INSTALLATION
Preparation
10
| HPA-O CS Plus
www.stiebel-eltron.com
9.3.2 Siting
Example: T-support SK 2
B
C
A
1
3
2
100
100
D
00000
63
48
6
1 Air intake side
2 Air discharge side
3 Main wind direction
Heat pump
A
B
C
HPA-O 3 CS Plus
850
500
408
HPA-O 4 CS Plus
850
500
408
HPA-O 6 CS Plus
980
500
408
HPA-O 8 CS Plus
980
500
408
!
Material losses
The T-support may bend if the heat pump is subject to
any lateral load.
f
Do not exert any pressure on the sides of the heat
pump.
f
Observe the structural limits of the T-support used.
To cover the supply lines, you can install a cover hood.
Note
You can install the cover hood either vertically or hori-
zontally.
f
Observe the installation instructions for the cover
hood.
200
358
200
190-400
D
00000
846
61
200
300-400
200
32
D
00000
846
62
Example: Wall mounting support WK 1
Note
To prevent disturbance due to structure-borne noise
transmission, never install the wall mounting bracket on
the external walls of living areas or bedrooms.
f
Install the wall mounting bracket on a garage wall,
for example.
Note
Condensate drips from the appliance onto the floor.
f
Observe the minimum clearance below the appli-
ance (see chapter "Preparations / Minimum clear-
ances").
≥200
2
3
1
D
00000
57
58
2
1 Heating flow
2 Heating return
3 Wall mounting bracket
f
Observe the structural limits of the wall mounting bracket
used.
To cover the supply lines, you can install a cover hood.
f
Observe the installation instructions for the cover hood.
200
95
200
190-400
D
00000
846
63