10
|HDB-E AU
www.stiebel-eltron.com
INSTALLATION
Shutdown
12. Shutdown
f
f
Isolate all poles of the appliance from the power supply.
f
f
Drain the appliance (see chapter "Installation /
Maintenance").
13. Alternative installation options
13.1 Electrical connection from above on unfinished
walls
26
�02
�02
�1
12
3�
f
f
Cut open the cable grommet for the power cable.
f
f
Push down the locking hook to secure the mains terminal.
Pull out the mains terminal.
f
f
Reposition the mains terminal from the bottom to the top.
Secure the mains terminal by pushing it under the locking
hook.
13.2 Large cross-section for electrical connection
from below
If you use cables with a large cross-section, you can fit the cable
grommet after the appliance has been installed.
1.
3.
4.
2.
26
�02
�02
�1
12
4�
f
f
Before installing the appliance, use a screwdriver to push out
the cable grommet.
f
f
Slide the cable grommet over the power cable. Use the in-
stallation aid supplied as part of the standard delivery. If
the cross-section is > 6 mm², enlarge the hole in the cable
grommet.
f
f
Push the cable grommet into the back panel. Click the cable
grommet into place.
13.3 Water installation on unfinished walls
12
D
00000
53
31
9
f
f
Seal and screw in the twin connectors (not included in stand-
ard delivery).
D
00000
41
72
4
2
3
1
3
1 Tee for cold water
2 Tee for domestic hot water
3 Cap
f
f
Fit the water connections.