PREPARATION
min 4
Ý
(102 mm)
48
Ý
(1219 mm)
Mount the hand dryer at least 48˝ (1219 mm) above the floor.
8. Preparation
The Galaxy
™
hand dryer must have its own independent circuit using 3 wire cable
of the appropriate size protected by a correctly rated double-pole circuit breaker.
The Galaxy
™
1 unit for 110 – 120 V requires a 20 A circuit breaker and AWG 12 copper
wire. The Galaxy
™
2 unit for 220 – 240V or 208 V requires a 15 A circuit breaker and
AWG 12 copper wire.
f
Transfer the four mounting points to the wall and trace the electrical wiring
entry point using the enclosed drilling template.
f
Feed the electrical wiring through the entry point traced with the template.
f
Remove the two screws at the air outlet grill and the screw on the locking slide.