6

Installation of the cable remote control in-
cludes a change of the control unit from the 
DHE to the wall mount and the fitting of the 
data transfer by telephone cable and connec-
tion module.

2.1 Regulations and specifications 

  The FB 1 SL connection module must be 

fitted and initially started up by a qualified 
installer, following these installation in-
structions.

  The operating and installation instructions 

for the instantaneous water heater must be 
observed on installation and operation.

  All electrical connections and installation 

work will be carried out in accordance with 
the VDE Rules (0100), the provisions of the 
electrical associations concerned and the ap-
propriate national and regional regulations.

  An installed unit will be switched off before 

retrofitting with a remote control.

  The cable seals supplied with the unit will 

be fitted as protection against penetrating 
water.

 Protection class IP 25 (spray water protect-

ed) is achieved only after the cover (

1

) has 

been installed on the heater. 

  The regulations specific to the country will 

be observed.

2.2 Installation location

The remote control is fitted at a clearly acces-
sible spot with the aid of the wall mount. They 
can be fitted in protection class 1 (IP X4 or 
IP X5). Assembly on a concealed switchbox or 
surface-mounted assembly.

Installation in an area subject to spray water 
from a hand-held shower is to be avoided.

Electrical equipment must in principle be used 
with due care to eliminate any potential risk 
through fire, electric shock or injury. The unit 
should therefore be used only as described 
in these instructions. Use disregarding the 
manufacturer‘s recommendations may result 
in damage or injury.

The instructions should be read carefully 
throughout before using the appliance and the 
advice given on proper handling of the unit 
should be followed.

!

Keep these instructions in a safe place 
and give them to the new owner if you 

move house. If maintenance or repair work is 
required, let the qualified installer have them 
for reference.

1. Operating instructions 

 for the user and installer

1.1 Description

FB 1 SL

 is a module for installing a cable re-

mote control for the Stiebel Eltron Instantane-
ous Water Heater 

DHE 18-27 SL(i) electronic 

comfort built from May 2005.

The cable remote control consists of the con-
trol panel for the instantaneous water heater 
and the wall mount for the module. The con-
trol panel is removed from the unit cover and 
inserted in the wall mount for the module. The 
remote control is installed at any desired place 
in the kitchen or bathroom.

The module connecting assembly built into the 
instantaneous water heater and linked to the 
remote control by a cable serves to transfer data 
between the remote control and heater.

The module panel is fitted into the DHE cover.

Scope of supply FB 1 SL  A :

 Cover (

1

) for the DHE unit cover

  Wall mount (

2

) to take the DHE control unit.

  Connection module (

3

)

  Fastening material for installation on the 

concealed switchbox.

1.2 Operation

!

Please see the operating and installa-
tion instructions for the instantaneous 

water heater for using the control unit. 

1.3 Safety information

  No changes of any kind may be made to the 

remote control.

  The remote control must not be used if a 

component is damaged, the remote control 
has fallen down or it was already malfunc-
tioning.

1.4 Care

A damp cloth is all that is needed to care for 
the housing. Don‘t use abrasive or aggressive 
cleaning agents. 

2. Installation instructions 

 for the qualified installer

2.3 Connecting cable for FB 1 SL

The remote control operates on safety extra-
low voltage. Connections up to 15 m in length 
are ensured for easy communication.
Control line:

  Telephone line type J-YY 2x2x0.6  

(without metallic screening)

The control line can be laid permanently con-
cealed or surface-mounted.

Screened cables may not be used under pro-
tection class 1.

2.4 Converting instantaneous wa-
ter heaters

– 

B

 open the cover on the heater (

4

), loosen 

the retaining screw (

5

). Remove the cover (

6

).

– 

C

 pull the plug for the thermostat fly lead 

cable from the heater.

– 

D

 remove the control unit (

8

) from the 

cover (

6

), pressing the 4 engagement hooks.

– 

E

 press the panel (

1

) into the cover, lodg-

ing on all 4 engagement hooks.

!

Don‘t fit a panel with damaged engage-
ment hooks. 

2.4.1 Electrical connection to the instanta-
neous water heater

F

 Feed the connecting cable optionally 

through the top (

9

) or bottom (

10

) available 

cable grommet. When connecting through the 
upper cable grommet (

9

), it must be cut back at 

the bevel in line with the cable cross section.
When connecting through the bottom cable 
grommet (

10

), the cable must be laid in the 

unit beneath the cable holders on the copper 
tank (heater).

Installing the connection module  G  

–  Strip the connecting cable for 35 mm and 

insulate the cable ends for 6 mm.

–  Open the connecting module housing by 

pressing in two of the catches on the side.

–  Connect the connecting cable to the termi-

nal strip (

11

), place in the cable bushing 

and re-close the housing.

– 

H

 insert the plug (

12

) into the „adapter“ 

point and place the connection module 
against the unit back wall top right. 

2.5 Remote control installation

2.5.1 Control unit installation

– 

I

 disassemble the two-part wall mount (

2

), 

by loosening the screws at the bottom (

17

).

–  pull the terminal strip component (

13

) from 

the lower part of the wall mount.

– 

J

 loosen the motherboard (

14

) from the 

control unit. Do so by pulling the board 
upwards with the thumbs at the bottom 
connector, loosening the three right-hand 
engagement hooks one after the other at 
the same time. 

– 

K

 replace the thermostat fly lead cable (

7

on the motherboard with the terminal strip 
component (

13

) from the wall mount. 

–  Reinsert the motherboard in the control unit, 

doing so by first inserting the motherboard 
on the left then pressing down to the right. 
Check the correct positioning of the unit 
centre line and drive lug on the knob (correct 
installation is not otherwise possible).

– 

L

 Press the control unit into the upper part 

of the wall mount. All 4 engagement hooks 
must nest.

2.5.2 Assembly of wall mount lower part

… on surface-mounted assembly of the con-
necting cable

– 

M

 punch out the knock-out points for the 

cable bushing (

15

) at the bottom of the wall 

mount (2 wall mount lower part knock-out 
points, 1 wall mount upper part knock-out 
point).

Summary of Contents for FB 1 SL

Page 1: ...CeC eC CZ HC HT V C C CZ HC VC CeC iV eV e V x V Z V BH HC VH HV CZ C C HeZ q V VZ Z Z HOHFWURQLF FRPIRUW...

Page 2: ...estimmungen 2 2 Montageort 2 3 Anschlusskabel f r FB 1 SL 2 4 Umbau Durchlauferhitzer 2 5 Bedienteilmontage Erstinbetriebnahme 5 Ersatzteile 5 Table of contents English page 6 7 1 Operating instructio...

Page 3: ...G C D E B electronic comfort 26_02_02_0715 26_02_02_0543 26_02_02_0707 electronic comfort 4 5 8 electron ic comfort 7 6 6 10 9 26_02_02_0688 3 26_02_02_0598 12 11 26_02_02_0686 300 35 6 t 300 mm 35 m...

Page 4: ...ktionen des Bedienteils ent nehmen Sie bitte der Gebrauchs und Montageanweisung des Durchlauferhitzers 1 3 Sicherheitshinweise Es d rfen keinerlei nderungen an der Fernbedienung vorgenommen werden Ist...

Page 5: ...f hren N Wandhalter durch die f r Schalterdosen passenden Ausbr che c mit beiliegenden Schrauben befestigen P O N M L K J I a 26_02_02_0709 13 14 7 13 15 b b a c c 16 2 17 26_02_02_0702 26_02_02_0705...

Page 6: ...ctions for the instantaneous water heater for using the control unit 1 3 Safety information No changes of any kind may be made to the remote control The remote control must not be used if a component...

Page 7: ...wo knock out points a The wall mount includes appropriate knock out points b for replacing an older remote control for assembly on concealed switchbox feed the connecting cable through the cable seal...

Page 8: ...Fax 020 720 9989 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 Fax 0387 7468 26 info stiebel eltron fr www s...

Reviews: