INSTALLATION 

 

Installation

EN

GL

ISH

www.stiebel-eltron-usa.com 

 DHX  15  Select | 

13

D00000

9

45

55

-b

f

Connected braided steel flex connectors (recommended for hot 
outlet, required for cold inlet, not supplied) to the twin ½˝ NPT 
male connectors.

f

Open the shut-off valve in the cold water inlet line.

When all plumbing work is completed, check for leaks and take 
corrective action before proceeding.

11.3 Electrical 

connection

WARNING: Electrocution

 

Before beginning any work on the electric installation, 
be sure that main breaker panel switches are “Off” to 
avoid any danger of electric shock. All mounting and 
plumbing must be completed before proceeding with 
electrical hook-up.  
The unit must be properly grounded in accordance with 
state and local codes, or in absence of such codes, in 
accordance with national electric code or the Canadian 
electric code. Failure to electrically ground the product 
could result in serious personal injury or death.

!

 

CAUTION:

 DO NOT INSTALL IN A BATH ENCLOSURE 

OR SHOWER STALL. DO NOT CONNECT TO A  

 

 SALT-REGENERATED WATER SOFTENER OR A WATER 

 

 SUPPLY OF SALT WATER. 

FOR USE ON AN INDIVIDUAL BRANCH CIRCUIT ONLY.

CAUTION: CONNECT ONLY TO A CIRCUIT PROTECTED BY A 
CLASS A GROUND FAULT INTERRUPTER

USE BONDING CONDUCTOR IN ACCORDANCE WITH THE CA-
NADIAN ELECTRICAL CODE, PART I

 

WARNING

 Electrocution

The connection to the power supply is only permissible as 
a permanent connection in conjunction with a ¾

˝

 Romex 

clamp. Ensure the water heater can be separated from 
the power supply by an isolator that disconnects all poles 
with at least 1/8

˝

 (3 mm) contact separation.

!

Supply this appliance only from a grounded system. A 
green terminal (or a wire connector marked “G”, “GR”, 
“GROUND”, OR “GROUNDING”) is provided for wiring the 
appliance. To reduce the risk of electric shock, connect 
this terminal or connector to the grounding terminal of 
the electric service or supply panel with a continuous 
copper wire in accordance with the electrical installation 
code.

!

 

Material losses

Observe the type plate. The specified rated voltage must 
match the supply line voltage.

f

All electrical work must comply with national and applicable 
state and local electrical codes.

f

The DHX should be connected to a properly grounded dedicat-
ed branch circuit of proper voltage rating. In installa tions with 
several DHX units, each unit requires an independent circuit. 
Please refer to the technical data table for the correct wire and 
circuit breaker size.

f

A 3/4˝ Romex clamp (required, not supplied) should be in-
stalled in the opening located between the hot and cold water 
connections. The wire should be fed through the Romex clamp. 
The “live” wires must be connected to the slots on the terminal 
block marked L and L. The ground wire must be connected 
to the slot marked with the ground symbol. See section 17.2, 
“Wiring diagram,” pg. 18.

4

Ǭ

5

ǩÝ

 (125–130 mm)

D00000

89

9

4

8-

a

11.4  Electrical connection with short power cable

If the power cable is not quite long enough, you can install the wiring 
block closer to the aperture in the water heater.

f

Reposition the wiring block from the top to the bottom. To do 
so, unclip the wiring block by pushing it firmly to the left and 
pulling it forwards.

Summary of Contents for DHX 15 Select

Page 1: ...gua Electr nicos sin Tanque DHX 15 Select Certi ed to ANSI UL Std 499 Conforms to CAN CSA Std C22 2 No 64 Certi caci n ANSI UL Std 499 Conforme a CAN CSA Std C22 2 No 64 Tested and certi ed by WQA to...

Page 2: ...1 10 1 Installation site_____________________________________________________11 10 2 Minimum clearances______________________________________________11 11 Installation_________________________________...

Page 3: ...12 3 Hook up electrical connections but keep circuit breaker off See section 11 3 Electrical connec tion pg 13 PLQ 1 2 D0000053277 4 Open and close all connected draw off valves at least 5 times for...

Page 4: ...ion the quali ed contractor must adjust the temperature set ting range to 122 F 50 C or less using the internal anti scalding protection on the water heater When using preheated water it must be ensur...

Page 5: ...n site damage f This symbol indicates that you have to do something The ac tion you need to take is described step by step 1 3 Units of measurement Note All measurements are given in inches millimeter...

Page 6: ...ensure that they never play with the water heater DAMAGE TO THE WATER HEATER AND THE ENVIRON MENT The water heater must be installed by a licensed electrician and plumber The installation must comply...

Page 7: ...ure the inlet tem perature will be displayed on the second row of the screen and will ash The water is not heated further DHX Select models are equipped with functions to permanently limit the tempera...

Page 8: ...play either after a 15 second period of time without user input or after a 5 sec ond hold of the Tmax button Changing the setpoint temperature Temperature settings Range Increment Range Increment 68 1...

Page 9: ...t 5 4 Recommended settings Your electric tankless water heater offers maximum precision and convenience for DHW production Should you nonetheless operate the water heater with a thermostatic valve we...

Page 10: ...e problem contact your quali ed contractor To facilitate and speed up your inquiry please provide the serial number from the type plate 000000 0000 000000 For live technical assistance please contact...

Page 11: ...ater ush to the wall The wall must have suf cient load bearing capacity 10 2 Minimum clearances D0000079442 f Maintain the minimum clearances to ensure trouble free oper ation of the water heater and...

Page 12: ...or will not pass the installation without a T P it should be installed on the hot water outlet side of the unit 11 2 1 Permissible water connection materials f The DHX s hot water outlet left is desig...

Page 13: ...power supply by an isolator that disconnects all poles with at least 1 8 3 mm contact separation Supply this appliance only from a grounded system A green terminal or a wire connector marked G GR GROU...

Page 14: ...09 F 50 C 122 F 60 C 140 F D0000094558 b Jumper position Description 38 C 100 F Code compliant hand washing applications 43 C 109 F Applications where risk of scalding may be a concern 50 C 122 F DHW...

Page 15: ...eater with preheated water For use in shower operation the valve must be set to a maximum of 131 F 55 C 12 4 Recommissioning Material losses To ensure that the Direct Coil heating system is not dam ag...

Page 16: ...t breakers are OFF to avoid any danger of electric shock f Open and close all connected draw off valves at least 5 times for at least 3 minutes total until all air has been purged from the pipework an...

Page 17: ...nit is faulty Replace the display only available with a new heater cover The PCB is faulty Replace the PCB Green flashing yellow on red off The outlet temperature does not match the set value The disp...

Page 18: ...output is subject to the connected power supply and the cold water inlet temperature The rated volt age and rated output can be found on the type plate Power output in kW 100 F DHW output in gpm Rated...

Page 19: ...cm Max conductivity 15 910 S cm Connections Water connections NPT Application limits Maximum permissible pressure 145 psi 1 MPa Maximum inlet temperature for reheating 131 F 55 C Maximum inlet tempera...

Page 20: ...ck 348144 10 Heating system 344147 11 Flow sensor 339979 12 Self resetting high limit safety cut out Klixon with outlet sensor 340528 13 Motorized valve 220502 14 Pipe elbow set 340542 15 Pipe elbow c...

Page 21: ...all warranties on Manufacturer s behalf and no statement warranty or guarantee made by any other party shall be binding on Manufacturer Manufacturer shall not be liable for any damage whatsoever rela...

Page 22: ...________________________________________31 10 2 Espacios libres m nimos__________________________________________32 11 Instalaci n _____________________________________________________32 11 1 Instalac...

Page 23: ...o mantenga el interruptor apagado Consulte la secci n 11 3 Conexi n el ctrica p g 33 PLQ 1 2 Abra el grifo Encienda la fuente de alimenta ci n D0000053277 4 Abra y cierre todas las v lvulas de salida...

Page 24: ...temperatura a 122 F 50 C o menos utilizando la protecci n interna antiquemaduras del calentador de agua Cuando se utilice agua preca lentada debe asegurarse de que la temperatura de entrada no supere...

Page 25: ...ntal Eliminaci n del aparato f Este s mbolo indica que usted tiene que hacer algo La acci n que debe realizar se describe paso a paso 1 3 Unidades de medida Nota Todas las medidas se dan en pulgadas m...

Page 26: ...estatales y locales de plomer a y electricidad El servicio del calentador de agua debe ser realizado por t cnicos de servicio cuali cados DA OS AL CALENTADOR DE AGUA Y AL MEDIO AMBIEN TE Este aparato...

Page 27: ...confort ininterrumpido y el suministro de agua caliente a la temperatura deseada en todo momento Si el calentador de agua funciona con agua precalentada y la tem peratura de entrada supera la tempera...

Page 28: ...a base La pantalla base se ala el valor nominal de temperatura actual en su unidad de temperatura preferida en la parte superior de la pantalla La barra que se encuentra debajo de la temperatura indic...

Page 29: ...Off el bloqueo no est activo La funci n de bloqueo est activa cuando en la pantalla se lee On Si el par metro de bloqueo de la pantalla est con gurado en On y el usuario sostiene el bot n de informaci...

Page 30: ...tador de agua no arranca a pesar de que la v lvula de agua corrien te est completamente abierta No hay electricidad Verifique si salt el in terruptor del panel de interruptores Reinicie si es necesari...

Page 31: ...arle sobre la resistividad el ctrica o la conductividad del agua en su rea 9 Descripci n del calentador de agua 9 1 Entrega com n Junto con el calentador de agua se entregan Malla de ltro instalada de...

Page 32: ...anel trasero del calentador de agua como gu a f Ponga el panel trasero del calentador de agua a un lado y tala dre los 2 agujeros marcados f Instale los anclajes de pared en la pared luego inserte y a...

Page 33: ...asa de la unidad para evitar da os Tenga en cuenta que el calor excesivo de las soldaduras no recomendado cerca del accesorio de entrada de agua fr a puede da ar la malla de pl stico del ltro situada...

Page 34: ...s trabajos el ctricos deben cumplir con los c digos el ctricos nacionales y estatales aplicables f El DHX debe ser conectado a un circuito dedicado de deriva ci n debidamente conectado a tierra y con...

Page 35: ...figuraci n de f brica Sin puente L mite 38 C 100 F f Instale el puente en la posici n requerida en la tira de clavijas Tmax PRECAUCI N Quemaduras Si el agua suministrada al calentador de agua se preca...

Page 36: ...espiral no se da e despu s de una interrupci n en el suministro de agua el calentador de agua debe reiniciarse siguiendo los siguientes pasos f Compruebe la presi n de suministro La lectura del man m...

Page 37: ...sedimentos incorporada que debe limpiarse peri dicamente f Apague el interruptor para desconectar la alimentaci n del calentador de agua f Cierre la v lvula de cierre para cortar el suministro de agu...

Page 38: ...ento La PCI no funciona correctamente Reemplace la PCI Verde parpadeante amarillo parpadean te rojo apagado La temperatura de salida no coincide con el valor esta blecido Se alcanz el l mite motorizad...

Page 39: ...100 D0000094547 b DHX b02 Cables el ctricos de entrada c01 Entrada de agua fr a Rosca macho NPT de pulg c06 Salida del ACS Rosca macho NPT de pulg 17 2 Diagramas de cableado DHX 15 Select L L 2 Tierra...

Page 40: ...ensi n nominal Temperatura de entrada de agua fr a Modelo p p 5 C 10 C 15 C 20 C DHX 15 Select 10 8 4 6 5 5 6 6 8 5 14 4 6 2 7 3 8 9 11 4 Potencia de salida en kW 50 C salida de ACS en l min Tensi n n...

Page 41: ...100 109 122 140 F 38 43 50 60 C ajuste de f brica 140 F 60 C Datos hidr ulicos Tasa de activaci n 0 264 gal 1 0 l min Capacidad nominal 0 07 gal 0 277 l Versiones Tipo de instalaci n Sobre el fregader...

Page 42: ...ntamiento 344147 11 Sensor de flujo 339979 12 Corte de seguridad de alto l mite con autorreajuste Klixon con sensor de salida 340528 13 V lvula motorizada 220502 14 Conjunto de codo de tubo 340542 15...

Page 43: ...irectivas del Fabricante o no observe los c digos de construcci n pertinentes 4 negligencia en cuanto a mantener el Calentador u operar el Calentador seg n las especi caciones del Fabricante 5 hacer f...

Page 44: ...MA 01088 Tel 413 247 3380 Fax 413 247 3369 info stiebel eltron usa com www stiebel eltron usa com A 353824 43819 9670 Subject to errors and technical changes Sujeto a errores y cambios t cnicos Sous r...

Reviews: