background image

iNSTallaTiON 

 

MaiNTENaNCE

14

 | DHM 6 220 www.stiebel-eltron.com

Activating the safety pressure limiter

D

00000

59

72

1

1

1  1-pole safety pressure limiter

14.  Maintenance

 

DANGER Electrocution

Before any work on the appliance, disconnect all poles 

from the power supply.

Draining the appliance

 

DANGER Scalding

Hot water may escape during the draining process.

If the appliance needs to be drained for maintenance or to protect 

the whole installation when there is a risk of frost, proceed as 

follows:

f

f

Close the shut-off valve in the cold water inlet line.

f

f

Open the draw-off valve.

f

f

Undo the water connections on the appliance.

Summary of Contents for DHM 6 220

Page 1: ...Hydraulically controlled mini instantaneous water heater DHM 6 220 OPERATION AND INSTALLATION...

Page 2: ...up and persons with reduced physical sen sory or mental capabilities or a lack of experience and know how provided that they are supervised or they have been instructed on how to use the appliance sa...

Page 3: ...Specification Data table Drain the appliance as described in chap ter Installation Maintenance Draining the appliance OPERATION 1 General information The chapter Operation is intended for appliance us...

Page 4: ...this information may result in non seri ous or minor injury 1 2 Other symbols in this documentation Note Notes are bordered by horizontal lines above and below the text General information is identif...

Page 5: ...ere is a risk of scalding at outlet temperatures in ex cess of 43 C DANGER Electrocution Any damaged power cables must be replaced by a qual ified electrician This prevents potential hazards from aris...

Page 6: ...heating system switches on automatically as soon as you open the DHW valve at the tap or activate the sensor of a sensor tap The water is heated The water temperature can be adjusted at the tap For th...

Page 7: ...ur qualified contractor To facilitate and speed up your request provide the serial number from the type plate 000000 0000 000000 DHM 6 220 Nr 000000 0000 000000 INSTALLATION 7 Safety Only a qualified...

Page 8: ...n 8 1 Standard delivery The following are delivered with the appliance Sieve inside the cold water inlet Special aerator SR Connection hose 3 8 500 mm long with gaskets Tee 3 8 Company logo for oversi...

Page 9: ...rost and near the draw off tap Ensure that the lateral fixing screws for the cover are always ac cessible The appliance is only suitable for undersink installation water connections at the top DANGER...

Page 10: ...crews by two turns f f Undo the snap fastener using a screwdriver f f Remove the appliance cover with the heater towards the front 26_02_05_0084 f f Using pliers break out the knock out for the power...

Page 11: ...nter the torque on the appliance using a size 14 spanner f f Fit the 3 8 connection hose provided and the 3 8 tee f f Install the tap For this also observe the tap operating and installation instructi...

Page 12: ...e A maximum cross section of 3 x 6 mm may be used Material losses When making the connection to a standard safety socket in the case of a power cable with plug ensure that the socket is freely accessi...

Page 13: ...e the appliance from the power supply by means of the fuse MCB in your fuse box or by pulling the power cable plug from the socket f f Drain the appliance see chapter Maintenance 13 Troubleshooting Pr...

Page 14: ...iance disconnect all poles from the power supply Draining the appliance DANGER Scalding Hot water may escape during the draining process If the appliance needs to be drained for maintenance or to prot...

Page 15: ...ance connector Appliance storage f f Store the dismantled appliance in a room free from the risk of frost as water residues remaining inside the appliance can freeze and cause damage Replacing the po...

Page 16: ...the designations on the socket terminals 15 3 Increasing the temperature 2 3 4 5 6 7 10 15 20 25 30 35 40 D0000041401 X Flow rate in l min Y Temperature increase in K 15 4 Application areas For the s...

Page 17: ...at 220 V 50 Hz 0 358 Connections Water connection G 3 8 A Values Max permissible inlet temperature C 35 ON l min 2 6 Pressure drop at flow rate MPa 0 09 Flow rate for pressure drop l min 2 6 DHW deliv...

Page 18: ...subsidiaries Such guarantee is only grant ed if the subsidiary has issued its own terms of guarantee No other guarantee will be granted We shall not provide any guarantee for appliances acquired in co...

Page 19: ...ENGLISH www stiebel eltron com DHM 6 220 19 GUARANTEE ENVIRONMENT AND RECYCLING GUARANTEE ENVIRONMENT AND RECYCLING...

Page 20: ...ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 Fax 0387...