17.3 Hot water output
The domestic hot water (DHW) output is subject to the connected
power supply, the water heater's connected load, and the cold water
inlet temperature. The rated voltage and rated output can be found
on the type plate.
Power output in kW
100 °F DHW output in gpm
Rated voltage
Cold water inlet temperature
Model
ĜŝƃŨp
ŝƃÄŨp
ŝÔƃŨp
41 °F
50 °F
59 °F
68 °F
DHC-E
3/3.5-1
Trend
3.0
0.35
0.41
0.5
0.64
3.5
0.41
0.48
0.58
0.75
DHC-E
4/6-2
Trend
2.9
0.34
0.4
0.48
0.62
4.5
0.52
0.61
0.75
0.96
3.8
0.44
0.52
0.63
0.81
6.0
0.69
0.82
1.0
1.28
DHC-E
8/10-2
Trend
5.4
0.63
0.74
0.9
1.15
7.2
0.83
0.98
1.2
1.54
7.2
0.83
0.98
1.2
1.54
9.6
1.11
1.31
1.6
2.05
DHC-E
12/15-2
Trend &
Plus
9.0
1.04
1.23
1.5
1.92
10.8
1.24
1.46
1.78
2.28
12.0
1.39
1.64
2.0
2.56
14.4
1.67
1.97
2.4
3.07
Power output in kW
122 °F DHW output in gpm
Rated voltage
Cold water inlet temperature
Model
ĜŝƃŨp
ŝƃÄŨp
ŝÔƃŨp
41 °F
50 °F
59 °F
68 °F
DHC-E
3/3.5-1
Trend
3.0
-
0.28
0.33
0.38
3.5
0.3
0.33
0.38
0.44
DHC-E
4/6-2
Trend
2.9
-
0.28
0.31
0.37
4.5
0.38
0.43
0.49
0.57
3.8
0.32
0.36
0.41
0.48
6.0
0.51
0.57
0.65
0.76
DHC-E
8/10-2
Trend &
Plus
5.4
0.46
0.51
0.59
0.68
7.2
0.61
0.68
0.78
0.91
7.2
0.61
0.68
0.78
0.91
9.6
0.81
0.91
1.04
1.21
DHC-E
12/15-2
Trend &
Plus
9.0
0.76
0.85
0.98
1.14
10.8
0.9
1.02
1.16
1.35
12.0
1.01
1.14
1.3
1.52
14.4
1.21
1.37
1.56
1.82
Power output in kW
38 °C DHW output in l/min
Rated voltage
Cold water inlet temperature
Model
ĜŝƃŨp
ŝƃÄŨp
ŝÔƃŨp
5 °C
10 °C
15 °C
20 °C
DHC-E
3/3.5-1
Trend
3.0
1.3
1.5
1.9
2.4
3.5
1.5
1.8
2.2
2.8
DHC-E
4/6-2
Trend
2.9
1.3
1.5
1.8
2.3
4.5
1.9
2.3
2.8
3.6
3.8
1.7
2.0
2.4
3.0
6.0
2.6
3.1
3.7
4.8
DHC-E
8/10-2
Trend
5.4
2.3
2.8
3.4
4.3
7.2
3.1
3.7
4.5
5.7
7.2
3.1
3.7
4.5
5.7
9.6
4.2
4.9
6.0
7.6
DHC-E
12/15-2
Trend &
Plus
9.0
3.9
4.6
5.6
7.1
10.8
4.6
5.5
6.6
8.5
12.0
5.2
6.1
7.5
9.5
14.4
6.2
7.3
8.9
11.4
Power output in kW
50 °C DHW output in l/min
Rated voltage
Cold water inlet temperature
Model
ĜŝƃŨp
ŝƃÄŨp
ŝÔƃŨp
5 °C
10 °C
15 °C
20 °C
DHC-E
3/3.5-1
Trend
3.0
1.0
1.1
1.2
1.4
3.5
1.1
1.3
1.4
1.7
DHC-E
4/6-2
Trend
2.9
-
1.1
1.2
1.4
4.5
1.4
1.6
1.8
2.1
3.8
1.2
1.4
1.6
1.8
6.0
1.9
2.1
2.4
2.9
DHC-E
8/10-2
Trend &
Plus
5.4
1.7
1.9
2.2
2.6
7.2
2.3
2.6
2.9
3.4
7.2
2.3
2.6
2.9
3.4
9.6
3.0
3.4
3.9
4.6
DHC-E
12/15-2
Trend &
Plus
9.0
2.9
3.2
3.7
4.3
10.8
3.4
3.8
4.4
5.1
12.0
3.8
4.3
4.9
5.7
14.4
4.6
5.1
5.9
6.9
17.4 Application areas/conversion table
Here, data is shown for electrical resistivity and electrical conduc-
tivity.
Standard specifica-
ŒêĒĉ|ŒĜÑŨ³
ŝƃŨ³
ŝÑŨ³
Min.
resistivity
ρ ≥
Max.
conductivity
ı
≤
Min.
resistivity
ρ ≥
Max.
conductivity
ı
≤
Min.
resistivity
ρ ≥
Max.
conductivity
ı
≤
Ωcm
mS/m
μS/cm
Ωcm
mS/m μS/cm
Ωcm
mS/m μS/cm
1100
91
910
970
103
1031
895
112
1117
17.4.1 Sizing the pipework
When calculating the size of the pipework, an water heater pressure
drop of 14.5 psi (0.1 MPa) is recommended.
17.5 Fault
conditions
In the event of a fault, temperatures up to 176 °F (80 °C) at a pressure
of 145 psi (1.0 MPa) can occur briefly in the installation.