Fault
Cause
Rectification
No hot water despite water flow
through the unit.
- The water flow volume
required for the unit
to turn it on has not
been reached.
- Increase flow volume
- Water flow too high
Reduce water flow
- Water flow too high
- Heating setting too low
- Turn knob to the right
(max. position)
- ELCB activated.
- Turn ELCB Reset
konb.