background image

4

 | DHC 

WWW.STIEBEL-ELTRON-USA.COM

INSTALLATION  

 

REGISTER YOUR PRODUCT

3.  Register your product

You must register this product within 90 days of pur-
chase on our web site in order to activate the standard 
warranty or to be eligible for the extended warranty. 
Go to our web site at 

www.stiebel-eltron-usa.com

 

and click on register your product.

Before beginning the registration process, we suggest that 
you gather the necessary information which will be as 
follows:

Type, Example: DHC (from the label that is on the unit)

Number listed after "Nr."  
Place of Purchase 
Purchase Date 
First & Last Name 
Email address 
Physical Address 
Phone Number 
Installation Date

IF YOU HAVE ANY QUESTIONS CONCERNING THE REGISTRA-
TION PROCESS OR WARRANTY OPTIONS, PLEASE CONTACT 
STIEBEL ELTRON USA DIRECTLY AT (800)-582-8423.

4. General

The DHC tankless water heater differs from conventional storage 
type water heaters in several ways.  It does not store hot water.  
Instead,  water is heated instantaneously as it flows through the 
unit.  The powerful heating elements are activated by a flow switch 
as water is drawn from a hot water faucet connected to the DHC.  
Due to the absence of stand-by losses,  the DHC has greater energy 
efficiency than storage type water heaters.

The temperature of the hot water delivered by the DHC depends 
on the wattage of the heating element,  the temperature of the 
incoming cold water,  and the water flow rate through the unit.  
In order for the DHC to operate properly,  it must be carefully 
matched to the application.

In case you have questions regarding the way you plan to use the 
DHC, please call our technical service line at 800-582-8423 (USA and 
Canada).  For service outside the U.S. and Canada,  please call us at  
USA 413-247-3380.  You can also e-mail us at info@stiebel-eltron-
usa.com or fax us at 413-247-3369.

The DHC can be used for hand washing type applications in the 
U.S. and Canada:

 

- Restroom sinks in commercial/industrial facilities and homes

 

- Kitchen areas in commercial /industrial facilities and homes

 

- Cabins

 

- Special uses in photo developing shops,  laboratories etc.

The DHC can also be used for whole apartments and homes in 
warm climate zones such as the Caribbean region,  Central Amer-
ica and Mexico due to the higher ambient water temperatures.

INSTALLATION

5.  Mounting the unit

26

_0

2_0

2

_0

33

0

7

6

1

4

3

2

8

5

1  Electrical junction box
2  Water supply line for faucet installation
3 3/8˝ compression-T
4 Shut-off valve
5  1/2˝ main pipe
6 Sink
7  Cold valve (right)
8  Hot valve (left)

DANGER:

 Electrocution 

The unit must be installed in a vertical position with 
the water fittings pointing downward. Do not install 
unit where it would routinely be splashed with water.  
Electric shock may result.

1.  Install DHC as close as possible to the hot water draw-off 

point,  for example,  directly underneath the sink or next to 
the shower stall.

2.  Install DHC in a frost free area.  If frost may occur,  remove 

unit before freezing temperatures set in.

3.  Leave a minimum of  5˝ of  clearance on all sides for 

servicing.

4.  Remove plastic cover.

26

_0

2_0

2_

13

6

0

5.  Mount unit securely to wall by putting two screws through 

mounting holes.  Screws and plastic wall anchors for mount-
ing on masonry or wood are provided.

Summary of Contents for DHC 10-2

Page 1: ...HC 10 2 Certi ed to ANSI UL Std 499 Conforms to CAN CSA Std E335 1 E335 2 35 Certi caci n con ANSI UL Std 499 Conforme a CAN CSA Std E335 1 E335 2 35 Certi la norme ANSI UL Std 499 Conforme la norme C...

Page 2: ...rmation_____________________________________________ 3 2 3 Safety Precautions_______________________________________________ 3 2 4 Test symbols ______________________________________________________ 3...

Page 3: ...egarding the installation use or opera tion of this water heater or if you need any additional installation manuals please call our technical service line see last side 2 3 Safety Precautions DANGER I...

Page 4: ...he application In case you have questions regarding the way you plan to use the DHC please call our technical service line at 800 582 8423 USA and Canada For service outside the U S and Canada please...

Page 5: ...ct the ame away from the housing of the unit in order to avoid damage 9 When all plumbing work is completed check for leaks and take corrective action before proceeding 7 Electrical connection WARNING...

Page 6: ...water temperature If temperature is too low the water ow rate needs to be reduced In order to do this turn off the unit s circuit breaker remove the cover and turn the ow adjustment screw shown in ill...

Page 7: ...rn clockwise See section 11 3 Temperature in crease above ambient water temperature pg 9 Voltage too low Supply correct voltage to unit If you are not able to resolve a problem please contact us toll...

Page 8: ...Twist cold water supply tube counterclockwise by 90 and pull towards bottom of unit Clean screen and put the screen the cold water supply tube and the ground wire back into their original position Pl...

Page 9: ...33 31 25 16 12 4 8 77 68 65 48 44 41 33 22 16 DHC 6 2 4 5 64 61 45 41 39 31 20 15 6 0 85 82 60 55 52 41 27 20 DHC 8 2 5 4 54 49 46 37 25 18 7 2 71 65 62 49 33 25 DHC 9 3 9 0 77 58 41 31 DHC 10 2 7 2 6...

Page 10: ...ressure drop at flow rate 0 023 MPa 0 023 MPa 0 023 MPa 0 023 MPa 0 023 MPa 0 023 MPa 0 025 MPa 0 03 MPa 0 03 MPa Pressure drop at flow rate 2 88 PSI 2 88 PSI 2 88 PSI 2 88 PSI 2 88 PSI 2 88 PSI 3 13...

Page 11: ...891 165891 165891 165891 6 Plumbing connection 170789 170789 170789 170789 170789 170789 170789 170789 170789 7 Housing front 165892 165892 165892 165892 165892 165892 165892 165892 165892 8 Safety th...

Reviews: