3. Register your product
You must register this product within 90 days of pur-
chase on our web site in order to activate the standard
warranty or to be eligible for the extended warranty.
Go to our web site at
www.stiebel-eltron-usa.com
and click on register your product.
Before beginning the registration process, we suggest that
you gather the necessary information which will be as
follows:
Type, Example: DHC (from the label that is on the unit)
Number listed after "Nr."
Place of Purchase
Purchase Date
First & Last Name
Email address
Physical Address
Phone Number
Installation Date
IF YOU HAVE ANY QUESTIONS CONCERNING THE REGISTRA-
TION PROCESS OR WARRANTY OPTIONS, PLEASE CONTACT
STIEBEL ELTRON USA DIRECTLY AT (800)-582-8423.
4. General
The DHC tankless water heater differs from conventional storage
type water heaters in several ways. It does not store hot water.
Instead, water is heated instantaneously as it flows through the
unit. The powerful heating elements are activated by a flow switch
as water is drawn from a hot water faucet connected to the DHC.
Due to the absence of stand-by losses, the DHC has greater energy
efficiency than storage type water heaters.
The temperature of the hot water delivered by the DHC depends
on the wattage of the heating element, the temperature of the
incoming cold water, and the water flow rate through the unit.
In order for the DHC to operate properly, it must be carefully
matched to the application.
In case you have questions regarding the way you plan to use the
DHC, please call our technical service line at 800-582-8423 (USA and
Canada). For service outside the U.S. and Canada, please call us at
USA 413-247-3380. You can also e-mail us at info@stiebel-eltron-
usa.com or fax us at 413-247-3369.
The DHC can be used for hand washing type applications in the
U.S. and Canada:
- Restroom sinks in commercial/industrial facilities and homes
- Kitchen areas in commercial /industrial facilities and homes
- Cabins
- Special uses in photo developing shops, laboratories etc.
The DHC can also be used for whole apartments and homes in
warm climate zones such as the Caribbean region, Central Amer-
ica and Mexico due to the higher ambient water temperatures.
INSTALLATION
5. Mounting the unit
26
_0
2_0
2
_0
33
0
7
6
1
4
3
2
8
5
1 Electrical junction box
2 Water supply line for faucet installation
3 3/8˝ compression-T
4 Shut-off valve
5 1/2˝ main pipe
6 Sink
7 Cold valve (right)
8 Hot valve (left)
DANGER:
Electrocution
The unit must be installed in a vertical position with
the water fittings pointing downward. Do not install
unit where it would routinely be splashed with water.
Electric shock may result.
1. Install DHC as close as possible to the hot water draw-off
point, for example, directly underneath the sink or next to
the shower stall.
2. Install DHC in a frost free area. If frost may occur, remove
unit before freezing temperatures set in.
3. Leave a minimum of 5˝ of clearance on all sides for
servicing.
4. Remove plastic cover.
26
_0
2_0
2_
13
6
0
5. Mount unit securely to wall by putting two screws through
mounting holes. Screws and plastic wall anchors for mount-
ing on masonry or wood are provided.