OPEraTiON 

 

General information

EN

GL

ISH

www.stiebeleltronamericas.com 

 DCE  Plus| 

5

OPEraTiON

1.  General information

Chapters "Special information" and "Operation" are intended for 

both users and qualified contractors.
Chapter "Installation" is intended for qualified contractors.

 

Note

Read these instructions carefully before using the water 

heater and retain them for future reference.

Pass on the instructions to a new user if required.

1.1  Safety instructions

1.1.1  Structure of safety instructions

!

 

KEYWORD Type of risk

Here, possible consequences are listed that may result 

from failure to observe the safety instructions.

 

f

Steps to prevent the risk are listed.

1.1.2  Symbols, type of risk

Symbol

Type of risk

 

 

Injury 

 

 

 

Electrocution 

 

 

 

Burns

(burns, scalding) 

1.1.3  Keywords

kEYWOrD

meaning

DANGER 

Failure to observe this information will result in serious 

injury or death.

WARNING 

Failure to observe this information may result in serious 

injury or death.

CAUTION 

Failure to observe this information may result in non-seri-

ous or minor injury.

1.2  Other symbols in this documentation

 

Note

General information is identified by the adjacent symbol.

 

f

Read these texts carefully.

Symbol

meaning

 

 

Material losses

(Water heater damage, consequential losses and environ-

mental pollution)

 

 

Appliance disposal 

 

 

f

This symbol indicates that you have to do something. The ac-

tion you need to take is described step by step.

1.3  Units of measurement

 

Note

All measurements are given in inches (millimeters) unless 

otherwise stated.

2.  Safety

2.1  Intended use

This water heater is suitable for heating domestic hot water or 

for reheating preheated water. The water heater can supply one 

or more draw-off points.
Water will not be reheated if the maximum inlet temperature for 

reheating is exceeded.
The water heater is intended for domestic use. It can be used 

safely by untrained persons. The water heater can also be used 

in non-domestic environments, e.g. in small businesses, as long 

as it is used in the same way.
Any other use beyond that described shall be deemed inappro-

priate. Observation of these instructions and of the instructions 

for any accessories used is also part of the correct use of this 

water heater.

2.2  General safety instructions

 

DANGER 

Burns

Water temperatures over 125 °F (52 °C) can cause se-

vere burns instantly or death from scalding. A hot water 

scalding potential exists if the thermostat on the water 

heater is set too high. Households with small children, 

disabled or elderly persons may require that the thermo-

stat be set at 113 °F (45 °C) or lower to prevent possible 

injury from hot water.

 

CAUTION 

Burns

If operating with preheated water, e.g. from a solar 

thermal system, the DHW temperature may vary from 

the selected set temperature.

!

!

Summary of Contents for DCE 10 Plus

Page 1: ...ntrolled electric tankless water heater Calentador el ctrico de agua sin tanque con control electr nico DCE 10 Plus DCE 13 Plus DCE 15 Plus Certified to ANSI UL Std 499 Conforms to CAN CSA Std C22 2 N...

Page 2: ...llation 10 9 2 Electrical connection 10 10 Commissioning 11 10 1 Internal anti scalding protection via jumper slot 11 10 2 Changing power output via the jumper slot only for models with selectable pow...

Page 3: ...9 3 Hook up electrical connections but keep circuit breaker off See section 9 2 Electrical con nection pg 10 3 min 1 2 D0000053277 4 Open and close all connected draw off valves at least 5 times for a...

Page 4: ...ith the water heater Children must never clean the water heat er or perform user maintenance unless they are supervised The water heater is suitable for supplying a shower in many climates shower oper...

Page 5: ...on Appliance disposal f This symbol indicates that you have to do something The ac tion you need to take is described step by step 1 3 Units of measurement Note All measurements are given in inches mi...

Page 6: ...st be used in order to maintain the IP 24 rating See section 9 1 4 Mounting the water heater pg 10 WARNING Injury The water heater may be used by children aged 3 and older and persons with reduced phy...

Page 7: ...king the following steps f Shut off power to the unit at the breaker panel by making sure that connected circuit breakers are OFF to avoid any danger of electric shock f Open and close the tap at leas...

Page 8: ...ise you of the electrical resistivity or conductivity of the water in your area 7 Water heater description 7 1 Standard delivery The following are delivered with the water heater Cable grommet Filter...

Page 9: ...n screen and put the screen back into its original position See section 15 2 Cleaning the filter screen pg 16 f The cold water connection inlet is on the right side of the unit and the hot water conne...

Page 10: ...k up Where required by local state or national electrical codes the circuits should be equipped with a ground fault interrupter The unit must be properly grounded in accordance with state and local co...

Page 11: ...limit the temperature with an upstream central thermostatic valve 10 2 Changing power output via the jumper slot only for models with selectable power output DCE 10 and 15 Plus feature selectable pow...

Page 12: ...alve must be set to a maximum of 131 F 55 C 10 5 Recommissioning Material losses To ensure that the Direct Coil heating system is not dam aged following an interruption to the water supply the water h...

Page 13: ...clicks into place f Install the water heater and connect the power cable to the wiring block as described in section 9 1 Standard non con cealed installation pg 10 f Seal the factory fitted cable grom...

Page 14: ...e heater with the screw Mounting the water heater D0000085464 b 2 1 1 Flat gasket 2 Filter screen with sealed edge f Mark the 4 drill holes referencing the positioning on the water heater rear cover f...

Page 15: ...er inlet is dirty Clean the filter screen See section 15 2 Cleaning the filter screen pg 16 The flow meter is not plugged in Connect the cable to the PCB The flow meter is faulty Replace the flow mete...

Page 16: ...nect the braided steel flex connector from the cold water inlet fitting right f To remove the filter screen from the bottom of the cold water inlet carefully insert a flathead screwdriver just above t...

Page 17: ...6 3 DHW output The DHW output is subject to the connected power supply the water heater s selected power output and the cold water inlet temperature The rated voltage and rated output can be found on...

Page 18: ...2 9 3 4 6 0 1 9 2 1 2 4 2 9 8 0 2 5 2 9 3 3 3 8 7 2 2 3 2 6 2 9 3 4 9 6 3 0 3 4 3 9 4 6 11 8 3 7 4 2 4 8 5 6 13 2 4 2 4 7 5 4 6 3 9 0 2 9 3 2 3 7 4 3 10 7 3 4 3 8 4 4 5 1 10 0 3 2 3 6 4 1 4 8 12 0 3...

Page 19: ...Values Max inlet temperature e g pasteurization F C 158 70 158 70 158 70 Activation rate gpm l min 0 264 1 0 0 264 1 0 0 264 1 0 Hydraulic data Nominal capacity gal l 0 07 0 277 0 07 0 277 0 07 0 277...

Page 20: ...re written authorization from Stiebel Eltron Inc The owner shall be required to show proof of purchase date and to pay all transportation costs to return the defective part s or instantaneous water he...

Page 21: ...ulta 29 9 2 Conexi n el ctrica 29 10 Puesta en marcha 30 10 1 Protecci n interna contra quemaduras a trav s de la ranura del puente 30 10 2 Cambiar la salida de potencia a trav s de la ranura del puen...

Page 22: ...nga el interruptor apagado Consulte la secci n 9 2 Conexi n el ctrica p g 29 3 min 1 2 D0000053277 4 Abra y cierre todas las v lvulas de salida conectadas al menos 5 veces durante al menos 3 minutos e...

Page 23: ...lizar tareas de mante nimiento del usuario a menos que lo hagan bajo supervisi n de un adulto El calentador de agua est dise ado para brindar duchas en muchos tipos de climas funcionamiento de ducha S...

Page 24: ...describe paso a paso 1 3 Unidades de medida Nota Todas las medidas se dan en pulgadas mil metros a menos que se indique lo contrario 2 Seguridad 2 1 Uso correcto Este calentador de agua es adecuado pa...

Page 25: ...VERTENCIA Lesiones El aparato puede ser utilizado por ni os mayores 3 a os personas con capacidades f sicas sensoriales o mentales reducidas y personas sin experiencia o conocimientos previos siempre...

Page 26: ...pci n en el suministro de agua debe seguir estos pasos para reini ciar el calentador de agua f Apague la alimentaci n el ctrica de la unidad en el panel de interruptores asegur ndose de que los interr...

Page 27: ...n dicada en la placa de identificaci n En una red de agua vin culada tenga en cuenta la resistividad el ctrica m s baja del agua Su empresa de suministro de agua puede informarle sobre la resistividad...

Page 28: ...g rese de descargar la l nea de suministro de agua fr a para eliminar las incrustaciones y la suciedad f La unidad DCE tiene una malla de filtro incorporada en la entrada de agua fr a que debe limpiar...

Page 29: ...deben utilizar tornillos avellanados para mantener la clasificaci n IP 24 D0000073844 f Conecte los conectores flexibles de acero trenzado recomen dado no suministrado u otra tuber a a los conectores...

Page 30: ...emaduras usando la perilla selectora de temperatura sin embargo cualquier tem peratura seleccionada que sea m s alta que el l mite Tmax ser ignorada y la temperatura de salida estar limitada al valor...

Page 31: ...la cubierta con el tornillo f Retire la pel cula protectora del panel frontal D0000053281 f Encienda la fuente de alimentaci n f Aseg rese de que la unidad de programaci n funciona correctamente D000...

Page 32: ...puj n dolo hacia adentro y hacia la izquierda hasta que haga clic y encaje en su lugar 12 3 Instalaci n oculta conexi n el ctrica desde arriba D0000073620 2 1 1 Pasa cables 2 Tendido de cables f Haga...

Page 33: ...de seguridad p g 24 Elimine los bordes afilados con una lima f Instale el m dulo de funciones en orden inverso en la cu bierta posterior del calentador de agua hasta que encaje en su lugar f Asegure e...

Page 34: ...a PCI no funciona correctamente Reemplace la PCI Verde intermitente amarilla encendida roja apagada La temperatura de salida no coincide con el valor estable cido La unidad de programaci n no estaba e...

Page 35: ...necte el conector flexible de acero trenzado del acceso rio de entrada de agua fr a derecha f Para quitar la malla de filtro de la parte inferior de la en trada de agua fr a inserte con cuidado un des...

Page 36: ...cableado 16 3 Salida del ACS La salida del ACS depende de la fuente de alimentaci n conec tada la salida de potencia seleccionada del calentador de agua y la temperatura de entrada del agua fr a El v...

Page 37: ...2 6 2 9 3 4 6 0 1 9 2 1 2 4 2 9 8 0 2 5 2 9 3 3 3 8 7 2 2 3 2 6 2 9 3 4 9 6 3 0 3 4 3 9 4 6 11 8 3 7 4 2 4 8 5 6 13 2 4 2 4 7 5 4 6 3 9 0 2 9 3 2 3 7 4 3 10 7 3 4 3 8 4 4 5 1 10 0 3 2 3 6 4 1 4 8 12...

Page 38: ...158 70 Tasa de activaci n gpm l min 0 264 1 0 0 264 1 0 0 264 1 0 Datos hidr ulicos Capacidad nominal gal l 0 07 0 277 0 07 0 277 0 07 0 277 Versiones Potencia de salida ajustable S No S Clase de prot...

Page 39: ...ob tener una autorizaci n por escrito de Stiebel Eltron Inc El propietario deber presentar un comprobante de la fecha de compra y pagar todos los costos de transporte para devolver la s pieza s defec...

Page 40: ...0 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 Fax 0387 7468 26 info stiebel eltron fr www stiebel elt...

Reviews: