20 |
SOKI 7 E plus | SOKI E trend
INSTALLATION
INSTALLATION
6.1.2 Installation on the cylinder
SOKI E trend:
D
00000
52
85
8
1
2
3
4
1
2
3
5
1 Twin nipple (G 1) for connection to the cylinder
2 Gasket
3 Union nut
4 Sensor well for the temperature sensor
5 Connection at the SOKI flow meter
SOKI 7 E plus:
D
00000
52
86
2
1
2
3
4
1
2
3
5
1 Twin nipple (G 1) for connection to the cylinder
2 Gasket
3 Union nut
4 Sensor well for the temperature sensor
5 Connection at the SOKI flow meter
with the cylinder connection set, the solar compact installation
can be fitted directly to the cylinder.
f
f
Fit the twin nipples from the cylinder connection set for
the flow and return into the connections of the solar indi-
rect coil in the cylinder and seal them in.
f
f
Using the union nut, secure the flow line of the cylinder
connection set.
f
f
To secure the return line to the solar compact installa-
tion, first remove the flow meter from the solar compact
installation.
f
f
Join together the flow meter and return line of the cylin-
der connection set.
f
f
Refit the flow meter to the pump assembly.
f
f
Using the union nut, secure the solar compact installation
to the twin nipple that you previously sealed into the
cylinder.