oPeRAtion
Maintenance, cleaning and care
www.stiebel-eltron.com
LWF FBF 160 |
9
EN
GL
ISH
D
00000
74
89
7
1
1 Locking tab
f
f
Push the filter frame towards the filter so that you can slide it
past the locking tab. Pull out the filter frame.
D
00000
36
94
9
1
2
1 Filter
2 Filter frame
f
f
Check to see how heavily contaminated the filter is.
If the filter is heavily contaminated (solid layer of dust or distinct
discolouration), you must replace the filter with a new one. If the
filter is only lightly contaminated, you can continue to use it.
f
f
If the filter needs to be replaced, remove it carefully and dis-
pose of it with household waste.
f
f
Clean the filter box, e.g. with a vacuum cleaner.
Replacement
filters
Thick
-
ness
[mm]
initial pres-
sure drop [Pa]
at 200 m³/h
Part
number
FMS FBF G4/10 20
20
234112
FMK M5-1
24
20
171475
FMK F7LP-1
48
26
233868
FMK F9-1
48
32
233869
FMK VOC-1
60
Approx. 50 - 60
Odour filter for
removing volatile
organic compounds
233870
D
00000
74
89
6
f
f
Insert the new filter. Pay attention to the direction of flow.
f
f
Check the filter for a correct, airtight fit.
D
00000
74
89
7
1
1 Locking tab
f
f
Insert the filter frame into the appropriate guide slot. At the
bottom, the filter frame is held in position in a V-shaped
groove. Push the filter frame down far enough that it clicks
into place below the locking tab.
D
00000
36
95
0
f
f
Position the cover on the filter box.
f
f
Secure the cover by tightening the star grip screws by hand.
f
f
Enter the maintenance data (date for next check) into the
label on the filter box.
f
f
If necessary, perform a filter reset on the control unit.
f
f
Switch the ventilation system back ON again.
f
f
Order new filters in good time.