INSTaLLaTION
Specification
20
| EIL Premium
www.stiebel-eltron.com
14.3 Tests in accordance with VDE 0701/0702
Earth conductor check
f
f
Check the earth conductor (in Germany e.g. DGUV A3) on the
earth conductor contact of the power cable and on the appli-
ance connector.
Insulation resistance
Due to the electronic control of this appliance, an insulation re-
sistance test to VDE 0701/0702 cannot be carried out.
f
f
To check the effectiveness of the insulating properties of the
appliance, we recommend conducting a differential cur-
rent test of the earth conductor current / leakage current to
VDE 0701/0702 (Fig. C.3b).
14.4 Appliance storage
f
f
Store the dismantled appliance free from the risk of frost, as
water residues remaining inside the appliance can freeze and
cause damage.
14.5 Replacing the power cable for the
EIL 6 Premium
f
f
If replacing the cable for the EIL 6 Premium, use a power
cable with 4 mm² cross-section
15. Specification
15.1 Dimensions and connections
95
28
30
120
143
190
4,8
165
82
20
b02
b03
c06
c01
D
00000
18
33
6
b02 Entry for electrical cables I
b03 Entry electrical cables II
c01 Cold water inlet
Male thread
G 3/8 A
c06 DHW outlet
Male thread
G 3/8 A