In most cases the factory default setting of high Sensitivity works fine, but
the sensitivity can be adjusted by changing the position of the slide switch
inside the SENSOR, as shown.
To adjust sensitivity:
Solar model
1. Remove the three screws on bottom side of SENSOR and remove the
cover.
2. Position the switch as shown for the desired sensitivity.
3. Close the cover, replace the screws and re-install the SENSOR.
Battery model
1. Unscrew the cap
2. Position the switch as shown for the desired sensitivity.
3. Replace cap.
There are two modes of code learning — ADDING A SENSOR or CLEAR ALL, both must be
performed while the SENSOR is a minimum of 10 feet from the RECEIVER.
Adding a Sensor
1. Disconnect power from the RECEIVER and wait 10 seconds.
2. Place the SENSOR a minimum of 10 feet from the RECEIVER. Wait 10 seconds.
3. Reconnect power to the RECEIVER. The green light will flash.
4. While the green light is flashing, press and hold the button down until you hear one beep
(approximately 2 seconds). Release button.
5. The red light on the RECEIVER will turn on, indicating the RECEIVER has entered its code
learning mode. NOTE: You now have 1 minute to teach your SENSOR.
6. Rotate or move the SENSOR. One beep will sound. If you have more than one SENSOR, only
activate one SENSOR at a time.
7. When all SENSORS have gone through the process, simply wait a minute or press and release
the button to exit the code learning mode.
Clear All
1. Disconnect power from the RECEIVER and wait 10 seconds.
2. Place the SENSOR a minimum of 10 feet from the RECEIVER. Wait 10 seconds.
3. Reconnect power to the RECEIVER. The green light will flash.
4. While the green light is flashing, press and hold the button down until you hear a series of
two beeps (approximately 5 seconds). Release button.
5. The red LED will be illuminated. Press and release the button to complete Clear All.
One year limited list accessories warranty. For returns, technical problems or warranty repair,
please contact the place of purchase. STI IS NOT LIABLE FOR LOST PROFITS, INDIRECT, SPECIAL,
EXEMPLARY, INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION ANY
SUCH DAMAGES DUE TO IMPROPER WIRING OR MISUSE OF THE PRODUCT.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
SENSITIVITY ADJUSTMENT
CODE LEARNING
Only necessary if RECEIVER or SENSOR is not working properly or to add more SENSORS. Note:
Maximum of four sensors can be programmed into each receiver.
WARRANTY
SOLAR MODEL
BATTERY MODEL