3.2.3 Remote Volume Control (cont.)
In order to remotely control the volume of the unit, a 10k-ohm potenti-
ometer should be placed between the +10V pin and the GND (Ground)
pin on the rear of the unit with its wiper on the RVC pin. The volume
will be determined by the selected resistance on the potentiometer,
the greater the resistance the louder the volume.
The amplifier can be remotely muted by making a connection between
the GND pin and the MUTE pin. No power should be applied to these
pins, simply a contact connection.