21
SEQUENCER
Outputs for remote
activation
Battery
Install it close
to the battery
(12” max.)
Radio / Player
STETSOM
- B
- A
INPUT
A
INPUT
B
HIGH INPUT
(AUTO TURN ON)
BLUE WIRE
WIRE GRAY
AUDIO OUTPUT
S1
S2
S3
Installation
Specification of the cables and fuse for proper installation:
▪ Power connectors (positive/negative)
.................................
▪ Remote connectors (REM IN / REM OUT )
..........................
▪
Fuse
......................................................................................
13 AWG
18 AWG
1A
POWER SUPPLY
13 AWG
cables
Fuse
1A
REM
18 AWG
cable
REM (remote)
INPUT
A B
+ A
+ B
Ground
▪
Installation must be done only by qualified professionals with the
product turned
OFF
.
▪
The use of fuse is mandatory to protect the system from short
circuit and overload. Install them as close to the battery as possible.