background image

7

R A N G E  A D J U S T M E N T

The sensor range is the greatest distance that an object can be away from the 
sensor to activate the faucet. The sensor is factory preset. If necessary, it may 
be adjusted as follows:

Adjusting  the  sensor  settings  with  a  remote  control  –  optional  and 
recommended:

The sensor range is the greatest distance that an object can be away from the 
sensor to activate the faucet. The sensor is factory preset. If necessary, it may 
be adjusted as follows

In order to adjust the sensor with a Remote Control you should hold the Remote 
Control straight in front of the sensor in a distance of about 4”(10cm). Choose 
the function you want to adjust by pressing once on one of the function buttons. 
After pressing once on a specific function button, a quick flashing of the red light 
in front of the sensor will occur. At this stage, you can change the adjustment 
by  pressing  the  (-)  or  (+)  buttons,  every  push  will  increase  or  decrease  one 
level.  After  finishing  the  adjustment,  turn  on 
the water supply. 

Range: 

Press  +  to  increase  detection  range 

and  –  to  decrease  the  detection  range  of  the 
sensor.

The  remote  control  can  also  be  used  to 
adjust:

Flow time (Security time):

 Press + to increase 

the security time and – to decrease it.

Delay In: 

Changes the time the water will start 

flowing when the user’s hands are within the sensor range. Press + to increase 
it and – to decrease it.

Delay Out:

 Changes the time of water flow after the user’s hands are removed. 

Press + to increase it and – to decrease it.

On/Off: 

Press this function button and the faucet will remain off for 1 minute. To 

cancel this function press the on/off again.

Reset: 

This function allows to come back to all the factory settings. Press the 

Reset button and without releasing it, press one time the + button. 

Summary of Contents for Extreme 1000 Plus B 237150

Page 1: ...1 INSTALLATION AND MAINTENANCE GUIDE E L E C T R O N I C L A V A T O R Y F A U C E T EXTREME SERIES...

Page 2: ...range 300 mm Security time 90 seconds Hot water temperature Max 70 C 1 TECHNICAL DATA 2 3 PACK CONTENTS 4 PRE INSTALLATION INFO 5 6 Faucet INSTALLATION RANGE ADJUSTMENT 7 Adjusting the sensor setting...

Page 3: ...treme B 237200 Extreme E 237300 Extreme 1000B 237100 Extreme 1000E 237000 Petite Extreme B 237600 Petite Extreme E 237700 Extreme Plus B 237250 Extreme Plus E 237350 Extreme 1000 Plus B 237150 Extreme...

Page 4: ...x Optional IP67 Battery Box Familiarize yourself with the part names and confirm that the parts are included ONE INLET battery versions 1 2 3 1 1x Faucet and attachments 2 1x Filter 3 1x Transformer O...

Page 5: ...attachments 2 2x Filters 3 1x Battery box Optional IP67 Battery box 1 2 3 1 1x Faucet and attachments 2 2x Filters 3 1x Transformer Optional Transformer with IP67 box 1 2 3 TWO INLETS battery versions...

Page 6: ...btain the missing parts Warnings Do not install the system facing a mirror or any other electronic system operated by an infra red sensor To prevent reflection problems it is recommended to keep a min...

Page 7: ...alnut thediskandthe gasket Do not remove the O ring from the base of the faucet Step 2 Installing the faucet 1 Place the faucet with O ring into the hole in the deck or lavatory Make sure the O ring i...

Page 8: ...valves angle valves 4 Check for leaks Step 4 Connecting the power source 1 Connect the power source a For battery versions install the battery s box at the wall underneath the sink using the two side...

Page 9: ...he red light in front of the sensor will occur At this stage you can change the adjustment by pressing the or buttons every push will increase or decrease one level After finishing the adjustment turn...

Page 10: ...power supply the sensor will not enter into adjusting mode and the previous setting will return 5 When the sensor enters into the adjusting mode and your hand is in front of the sensor a slow flashin...

Page 11: ...or light will blink at a constant rate The battery must be replaced within two weeks To replace the battery at battery models 1 Carefully open the battery s box 2 Remove the old battery 3 Replace the...

Page 12: ...ove the filter s and wash it them under running water 4 Reassemble the parts 5 Make sure that there is no water leakage Care and cleaning of chrome and special finishes DO NOT use steel wool or cleans...

Page 13: ...ntrol Mixing valve for one inlet models IP 67 Battery box with 6 x 1 5V AA batteries IP 67 Transformer box with 300 mA transformer Power splitter 2 ways Power splitter 3 ways Power splitter 4 ways Cat...

Page 14: ...ssure that the backcheck prevents from dropping even after water supply pressure drops under 8 bars Debris or scale in diaphragm 1 Sensor is dirty or covered 2 Sensor is picking up reflections from th...

Page 15: ...ise see STERN Warranty The guarantee does not cover faults labour costs or damage caused by incorrect installation and or maintenance wear and tear battery or water composition This includes but is no...

Page 16: ...14 15 Gan Rave Blvd 81222 Gan Rave Yavne Israel Tel 972 8 9326000 Fax 972 8 9326025 export sternfaucets com www sternfaucets com 03 09 015237100...

Reviews: