15
SETTINGS ADJUSTMENT
DELAY OUT TIME:
This function allows modifying the time the flush
valve will deliver water after the user leaves the W.C. In this case,
a delay out time close to 0 will not give the user the possibility to be
away from the sanitary. An increased delay out time will make the
user experience more comfortable, but high traffic of users should
be taken into consideration. If required, the delay out time can be
modified as follows:
Press the OUT button. Wait until a quick flashing of the red light at
the sensor eye is perceived. Then, press + to increase the delay
out time and – to reduce it.
TEMPORARY OFF FUNCTION:
This function is ideal to perform any
kind of activity in front of the sensor without operating the system
(for example, cleaning).
The flush valve will remain shut for 1 minute when this button
is pressed once. To cancel this function and to return to normal
operation press the On/Off button again or wait 1 minute.
RESET BUTTON:
This function restores all the factory settings
except for the sensor range. If required, press the Reset button
and without releasing it, press the + button once.