8
SETTINGS ADJUSTMENT
DETECTION RANGE:
The sensor range is the greatest distance
that an object can be away from the sensor to activate the faucet.
The sensor is factory preset.
To adjust the sensor range press + to increase detection range
and – to decrease the detection range of the sensor.
SECURITY TIME:
The Security time, prevents continuous flushing
of water due to reflections or vandalism. By default, if the sensor
is covered for more than 90 seconds the water flow will shut
automatically. To resume regular operation any obstruction must be
removed.
Press the SEC button. Wait until a quick flashing of the red light of the
sensor eye is perceived. Then, press + to increase the security time
and – to reduce it.
DELAY OUT TIME:
This button allows modifying the water flow time
after the user removes his hands from the faucet. A delay out time
close to 0 will save more water. An increased delay out time will make
the user experience more comfortable.
If required, the delay out time can be modified as follows:
Press the OUT button. Wait until a quick flashing of the red light of the
sensor eye is perceived. Then, press + to increase the delay out time
and – to reduce it.
TEMPORARY OFF FUNCTION:
This function is ideal to perform any
kind of activity in front of the sensor without operating the system
(for example, cleaning).
Faucets will remain shut for 1 minute when this button is pressed
once. To cancel this function and to return to normal operation
press the On/Off button again or wait 1 minute.
RESET BUTTON:
This function allows the sensor to return to the
original factory preset settings.
If required, press the Reset button and without releasing it, press
the + button once.