background image

Battery Ty

p

e Select

i

o

n

If onl

y tw

o b

a

t

teries are used wit

h

a 3-bank c

h

arger, then connect the unused

o

u

tpu

t

cab

l

e

t

o

eith

er o

ne

o

f

th

e

two

bat

teries

,

as instructed

i

n ite

m

8 above.

A

l

way

s c

on

n

ect each charger output

t

o a s

i

ng

l

e 12V batter

y

even if the batter

i

es are

w

ir

ed in se

ri

es f

or 24

V

o

r

3

6V

.

Output No

.

1

Output No

.

2

ProS port 8, 12 and

2

0

Wiring Diagram

IMPORTANT NOTICE: Lead-Acid Gel Battery Selector

The ProSpor! battery charger is factory set for lead-acid batteries. It can be reset for gel
batteries by using the one-time gel selector

.

This selector is simply a jumper on the side

of the charger where the DC cables are located. By cutting and removing the jumper
the ProSpor! will be set for gel batteries. After cutting the jumper fill the dimpled area
with a marine grade silicon sealant

.

Please contact Sterling Power Products if you have

any questions regarding the correct battery type setting

.

This is a one-time selector.

L

i

v

e

(

b

row

n

o

r

bl

a

ck

)

Neut

r

al

(

bl

u

e or

w

h

i

te

)

E

ar

t

h

(y

e

ll

o

w

-

gr

e

e

n

)

~atteryType

·

SelectQr

(

yel

l

o

w w

ire o

n

side of

ch

a

r

ge

r)

seale

d

+

ge

l

batter

i

es

:

cut ye

l

l

ow w

ire

open lea

d

-acid

batte

r

ies

:

l

eave

co

n

nected

DD

• Charg

i

ng Ba

t

teries

Output No

. 1

Outp

u

t No. 2

Output N

o. 3

ProS

po

rt

20plus

Wi

ring D

ia

g

ram

The Sterling ProSpor

t s

eries is designed to charge

,

c

o

ndition and maintain

y

our batterie

s.

P

l

ease follo

w

these

steps each time you use your ProSpo

r

t charger

.

1

.

Open all batter

y

compartments and

v

entilate for at least 15 minutes before appl

y

ing

A

C po

w

er to

y

our

charger

. W

hile charging

y

our batteries make sure to keep

y

our batter

y

compartment open

,

allo

w

ing for free air

v

entilation.

2. Make sure all DC batter

y

connections are t

i

ght and clean

.

Follo

w

the batter

y

manufactu

r

er

'

s

recommendation for battery cell caps

.

Loosen caps if applicabel

.

3. Connect a

hea

v

y

duty extension cord to the ProSpo

r

t charger first

.

After connecting the e

x

tension cord to

the charger proceed to plug the extension cord to a nearb

y

RCD-protected AC po

w

er outlet

.

4. Obser

v

e the on

-

board LED indicators for a solid green and red indication

.

This

w

ill tell

y

ou the batte

r

ie

s

are

in the charging process.

5. Charge

y

our batte

r

ies until onl

y

the g

r

een LED indicator remain

s

on. This indicates that the charging

process is comple

t

ed and

y

our batteries are fully charged and are no

w

being maintained in a gentle float

/

storage mode. (Recommended

w

hile your boat is not in use.) The ProSport can be left on in this mode

indefinitely and

w

ill ne

v

er o

v

ercharge

y

our batteries

.

6. W

h

en ready to use you

r

boat

,

unplug the e

x

tension cord from the AC po

w

er out

l

et first

,

follo

w

ed by

unplugging the charger

.

Domestic

Batter

y

1

Engine Start Batter

y

or Domestic Batter

y

2

Li

v

e

(

brown or b

l

ack)

Neutr

al

(

b

lu

e or

w

hite

)

E

a

rth

(

y

e

l

lo

w

-gr

ee

n)

o

[J

0

Domesti

c

Batter

y

1

Domestic

B

a

tter

y

2

Engine Start Batter

y

or Domestic Batter

y

3

Summary of Contents for ProSport 8

Page 1: ...Produktes erfolgt unter der Bedingung und Vereinbarung dass Sterling Power Products Ltd keine Haftung fur Neben oder Folgeschiiden jeglicher Art ubernimmt Dies gilt nicht in Liindern die solche Aussc...

Page 2: ...may result in risk of electrical shock or fire To reduce the risk of electrical shock remove AC power from the charger prior to any maintenance or cleaning WARNING RISK OF EXPLOSIVE GASES Working in t...

Page 3: ...port PS1212 2 bank charger No problem because the unused 10 amps will be automatically distributed to the domestic battery bank A conventional 12 amp charger could only provide a total of 6 amps to th...

Page 4: ...the batteries there will be a brief low power spark that is generated as you make the connection This is due to the high frequency capacitors taking a charger Make sure the black or yellow wires are c...

Page 5: ...your batteries Please follow these steps each time you use your ProSport charger 1 Open all battery compartments and ventilate for at least 15 minutes before applying AC power to your charger While c...

Page 6: ...DC lead acid factory setting ProSpor Conditioning The ProSpar will hold batteries at 14 6V DC factory set for lead acid batteries to complete charging while conditioning batteries by desulfating each...

Page 7: ...ery should be tested with a hydrometer with the charger and the engine off to determine if one or more batteries have bad cells Batteries should always be replaced in sets and always the same type D I...

Page 8: ...ondition and agreement that Sterling Power Products Ltd shall not be liable for incidental or consequential damages of any kind Some countries do not allow the exclusion or limitation of incidental or...