Page 25
! CAUTION !
Never close the chamber access doors without checking that all three (3)
segregation chambers are in place and hand knobs are tight. Never attempt to run
machine without all three (3) segregation chambers in place and tightened.
Always wear heavy gloves and exercise care when working in the cutting
chamber.
4-5 Shutdown
Conditions
4-5-1 Emergency
Stops
Feedstock must be cleaned out of the hopper and cutting chamber
prior to restarting.
4-5-2 Temporary
Machine
Stops
To temporarily stop the machine,
first
allow all material to run out
of the cutting chamber.
Never
try to restart the machine with
material remaining inside the cutting chamber.
4-5-3 Final
Machine
Stops
To shut the machine down, allow all material to pass through the
transition before pressing the STOP pushbutton to stop the
machine.
! CAUTION !
This model series of granulator is NOT designed to grind purgings, large chunks
of solid plastic, or other heavy cross-sectional pieces.