Specification:
12V-12V 60A
Current limiting
Thermostatic control fan
Auto or ignition feed
SETUP
ENTER
Background
light
on
unit
active
www.sterling-power-usa.com
www.sterling-power.com
Designed and
developed
in England
Made in Taiwan
technology
4
L : DUR
A
A
IT
B
L
IG
E
D
:
:
D
C
E
I
M
S
A
G I
N
N
Y
D
ProDigital
To remove lid gently press the sides in no more
than about 4 mm and slide out the lid.
1
2
3
4
5
7
10
11
8
9
14
+
+
+
+
+
+
Remote control
Battery
temperature
sensor
Rem V sense
see side
info
label
SETUP
ENTER
SELECT
Reverse
polarity
tell
Enter/Select
buttons under cover
f
u
s
e
Reverse
polarity
tell
f
u
s
e
f u e s
regen
braking
Bat
in +
Bat
out +
Neg
-
12
13
6
The mm2 figures have been rounded up to suit European cable availability.
20A
Distance
3m (10 ft) 5m (15ft) 7m (22ft) 8m (25ft) 9m (30ft)
mm2 /
2.5 /
2.5 /
4.0 /
4.0 /
6.0 /
AWG
14
14
12
12
10
30A
Distance
3m (10 ft) 5m (15ft) 7m (22ft) 8m (25ft) 9m (30ft)
mm2 /
6.0 /
6.0 /
6.0 /
6.0 /
10.0 /
AWG
10
10
10
10
8
40A
Distance
3m (10 ft) 5m (15ft) 7m (22ft) 8m (25ft) 9m (30ft)
mm2 /
10.0 / 10.0 / 10.0 / 10.0 /
16.0 /
AWG
8
8
8
8
6
50A
Distance
3m (10 ft) 5m (15ft) 7m (22ft) 8m (25ft) 9m (30ft)
mm2 /
16.0 / 16.0 / 16.0 / 16.0 / 16.0 /
AWG
6
6
6
6
6
60A
Distance
3m (10 ft) 5m (15ft) 7m (22ft) 8m (25ft) 9m (30ft)
mm2 /
16.0 / 16.0 /
16.0 / 16.0 / 25.0 /
AWG
6
6
6
6
4
Nominal
Fuse size for
input & output
30A
40A
50A
70A
80A
Recommended cable size for current required
Under the lid
1) DC output fuse
2) Negative fuse (position, model dependent)
3) DC output to aux battery
4) Common negative
5) DC input from start battery (green connector or
brass nut/bolt - model dependent).
6) DC input fuse
7) Remote control socket
8) Low Voltage (regenerative braking)
9) Ignition feed connector
10) Auto regen. mode (default w/ ign feed)
11) Remote battery sense wire to compensate for
voltage drop in cable (optional, does not need to
be used).
12) Battery temperature sensor, optional fit, if not
used product will work on default of 20 deg C
setting.
13) Other wire associated with the temp sensor as
per 12.
14) Reverse polarity tell tale diodes. If damaged,
will show if unit has been reverse polarity and not
under warranty. Position of diodes are model
dependent.
Models:
BB1260 / BB122470 / BB123670 / BB124870 /
BB242435 / BB241235
S
TERLI G
P
OWER
Models:
BB1230
BB122440
Front Panel II
+
+
+
+
+
+
+
+
+
8
1
2
3
4
6
7
10
11
12
13
9
5
14
+
+
+
+
+
+
+ +
5
3
4
1
6
BB122470
BB123670
BB124870
BB1260
BB242435
BB241235
einfache
Entfernung
1m
2m
3m
4m
5m
Empf.
Sicherung
30A Gerät
6mm²
10mm²
16mm²
16mm²
25mm²
50A
60A Gerät
16mm²
25mm²
25mm²
35mm²
35mm²
100A
Stationary vehicle engage mode.
Unit on at 13.1V input.
When input below 12.9V, a 20 second
timer starts - if still below 12.9V after the 20
seconds the unit goes to sleep. Requires
13.1V to come on again.