Colour indicator
Diagnosis
Low temperature alarm
Between 15 °C and 17 °C
Too low temperature alarm
Less than 15 °C
High temperature alarm
Higher than 34 °C
Control box temperature too high
Colour
indicator
3 flashes / 6 seconds (chlorinator)
3 flashes / 6 seconds (chlorinator)
2 flashes / 6 seconds (chlorinator)
1 flash / 6 seconds
Possible
causes
Water Temperature low.
Water temperature less than 15 °C or
temperature sensor disconnected.
Water temperature high.
The control box temperature is rising.
The pool plant temperature is too high.
Solutions
The water is getting cold, the alarm
indicates that you are nearing the safety
temperature that will stop the chlorinator.
The water is too cold, the chlorinator stops
producing. If the water temperature does not
match the value displayed on the app: check
the sensor connection. Reconnect the sensor
to the control box. Check the sensor condition.
If necessary, replace the sensor (possibility of
calibrating the sensor, refer to the manual).
To protect your pool coating (liner/reinforced PVC),
it is important to lower the water temperature.
Open the slatted cover or the pool shelter.
Run the filtration continuously.
Check the pool plant temperature.
Ventilate the pool plant if necessary.
Self reset
Yes
Yes
Yes
Yes
Click the symbol
7. |
Control box colour code: operating diagnosis
7
S
tatuses and anomalies
45
Stérilor XP Temperature