background image

1

2

3

4

5

6

When the XP range products are first installed, the professional or owner must create an account. 

Follow the steps:

1

Create an account

2

Enter the requested 

information

3

Enter a password compliant 

with the instructions

4

If you are a professional, 

check the box and then 

enter the Company name 

and Siret number

5

Read and validate the 

Stérilor terms and 

conditions.

6

Validate the registration

Important information:

•  Smartphone connection to the 

internet mandatory for a Cloud 

connection

•  Each user must have their 

personal Stérilor XP account

M

an

d

at

or

y i

nt

er

n

e

t

 co

nn

ec

ti

 o

n

3. | 

Installer or User account creation

3

Setting up the Stérilor XP app

22

Stérilor XP Temperature

Summary of Contents for XP Connect

Page 1: ...Installation and user manual Stérilor XP Temperature ...

Page 2: ...20 3 Operation using Stérilor XP Connect 21 3 Installer or User account creation 22 3 Create a pool account 23 3 My pool address 24 3 My pool my equipment 25 4 Device Stérilor XP app installation 4 Pairing the first control box with the app 26 4 Pairing another control box with the app 27 4 Installed sensor identification 28 4 Temperature display 29 4 Manual Water temperature calibration 30 5 My S...

Page 3: ... Choose complete treatment straight away or upgrade your solution depending on your wishes and your budget Stérilor XP modules are stand alone complementary and interconnected using Bluetooth Stérilor XP Sel Stérilor XP Redox Stérilor XP Temperature Stérilor XP Connect Stérilor XP pH 1 The complete Stérilor XP range 1 1 Device discovery 3 Stérilor XP Temperature ...

Page 4: ...nt temperature range 0 C t C 55 C Protection rating IP66 Marking This product is compliant with directives 2014 30 EU 2014 35 EU and 2014 53 EU The installation must be carried out by authorised staff The electricity installation must be compliant with the NF C 15 100 or HD 60364 or IEC 60364 standards The pool water quality must be compliant with the NF EN 16713 3 standard The salt chlorinator mu...

Page 5: ...reaches or exceeds 34 C an alarm message is displayed The Temperature control box notifies the XP chlorinator to stop chlorine production when the pool water temperature drops below 15 C POSSIBLE SETTINGS Possible settings temperature measurement adjustment offset 1 Stérilor XP Temperature operating principle 1 Device discovery 5 Stérilor XP Temperature ...

Page 6: ...The Stérilor cell must be installed with the connection head at the bottom 1 Vessel and module configuration possibilities 1 Device discovery 6 Stérilor XP Temperature ...

Page 7: ...and Ø 63 mm connectors 5 accessory holder with Ø 50 mm and Ø 63 mm connectors Valve with fittings for drainage or water analysis sample taking Connection Ø 75 mm Screw on connector Ø 75 mm KAQ4044 KAQ4103 KAQ4104 KAQ4279 KAQ4030 KAQ4107 1 Accessories available as options 1 Device discovery 7 Stérilor XP Temperature ...

Page 8: ...7 6 Alkalinity T A C between 80 and 150 ppm Hardness TH between 150 and 250 ppm Free chlorine between 0 3 and 1 5 ppm Stabiliser Max 30 mg l Salt if XP Chlorinator Between 3 5 and 5 g l 1 Water quality recommendations 1 Device discovery 8 Stérilor XP Temperature ...

Page 9: ... once per month and adjust if necessary Couple the Stérilor XP Temperature electric connection to the filtration Provide for a connection to a 6A circuit breaker coupled to the filtration Install the sensor before any treatments or product injections There are no pitch constraints for the Temperature sensor installation head at the top the bottom or at 90 FOR OPTIMUM STÉRILOR XP TEMPERATURE OPERAT...

Page 10: ...er cord 2 accessory holder with its connectors Ø 50 mm and Ø 63 mm Installation Wall support Sensor holder and gasket 3 screws and 3 anchors to install the box Temperature sensor 2 Pack contents 2 2 Device installation 10 Stérilor XP Temperature ...

Page 11: ...ndpaper to debur fine grain PVC scourer High performance PVC ABS adhesive Cloth Drill Ø 5 mm drill bit Cross tipped screwdriver Stripping pliers 2 Equipment required for the installation 2 Device installation 11 Stérilor XP Temperature ...

Page 12: ...t module Or installed before the chlorination vessel Manifold Skimmers Pump To drains Heat pump Filtration unit To backflow nozzles Swimming pool backflow Main drain Filter 230 VAC 2 Possibility 1 installation of the 2 accessory module 2 Device installation 12 Stérilor XP Temperature ...

Page 13: ...dule Or installed before the chlorination vessel Manifold Skimmers Pump To drains Heat pump Filtration unit To backflow nozzles Swimming pool backflow Main drain Filter 230 VAC Bypass 2 Possibility 2 installation of the 2 accessory module 2 Device installation 13 Stérilor XP Temperature ...

Page 14: ...rease when fitting the gaskets Tighten the nuts by hand all tightening tools are prohibited The 2 part nuts cannot be dismantled Do not use nuts that have been dismantled Clip the Stérilor ring at the location you have selected Maintain the module ends in position using suitable ties not included POSSIBILITY OF INSTALLING THE MODULE INDEPENDENTLY OF THE CHLORINATOR VESSEL Install the module after ...

Page 15: ... piping Install the module upstream of the chlorination vessel The Temperature sensor must be installed vertically or horizontally with the measuring head at the bottom or top Water flow direction Temperature sensor 2 Installing the 2 accessory module connected to the chlorination vessel 2 Device installation 15 Stérilor XP Temperature ...

Page 16: ...lso be stopped Control box electric connection staff qualified for electric connections Cut off the electricity supply before connecting Place the control box at a height of about 1 50 m Fix the support using the 3 supplied screws and 3 the anchors drill hole Ø 5 mm Use the built in level to correctly position the support Simply clip the control box onto its support Control box clips towards the t...

Page 17: ... to the 2 pole control box connector Tighten the nut manually Do not use tightening tools Control box 2 pole connector Tightening nut Sensor 2 pole connector 2 Temperature sensor connection 2 Device installation 17 Stérilor XP Temperature ...

Page 18: ...nnected to the internet M an d a t o r y internet co n n e c t io n Stérilor XP pH Stérilor XP Connect Stérilor XP Temperature Stérilor XP Redox Stérilor XP Sel SIMPLE FUNCTIONAL USER FRIENDLY ERGONOMIC 3 The Sterilor XP App 3 3 Setting up the Stérilor XP app 18 Stérilor XP Temperature ...

Page 19: ...e You can download it QR code to download the Stérilor XP app From Android 7 0 or later From iOS 10 0 or later AVAILABLE FROM DOWNLOAD FROM App Store Stérilor XP AS Pool 3 Stérilor XP application download 3 Setting up the Stérilor XP app 19 Stérilor XP Temperature ...

Page 20: ... the devices using the Bluetooth on a phone connected to the internet Or Home Pool plant Adsl Vdsl Fibre 2 4 or 5 Ghz 3 Operation without Stérilor XP Connect 3 Setting up the Stérilor XP app 20 Stérilor XP Temperature ...

Page 21: ...ng a phone connected to the internet Pool plant Home Adsl Vdsl Fibre Bluetooth Only required for the 1st installation and device update Or 2 4 or 5 Ghz 2 4 Ghz 3 Operation using Stérilor XP Connect 3 Setting up the Stérilor XP app 21 Stérilor XP Temperature ...

Page 22: ...professional check the box and then enter the Company name and Siret number 5 Read and validate the Stérilor terms and conditions 6 Validate the registration Important information Smartphone connection to the internet mandatory for a Cloud connection Each user must have their personal Stérilor XP account M an d a t o r y internet co n n e c t io n 3 Installer or User account creation 3 Setting up ...

Page 23: ...le to use the Stérilor XP app for your pool Follow the steps To access your full device manual follow steps 5 and 6 1 Create a pool 2 Enter your pool name 3 Validate the creation 4 Access to the Home page 5 Press Information 6 Press User manual M an d a t o r y internet co n n e c t io n 3 Create a pool account 3 Setting up the Stérilor XP app 23 Stérilor XP Temperature ...

Page 24: ...Address 3 Enter the pool location address 5 The address is identified on the app 4 Select the address The address is used to locate the pool 6 The weather information is indicated 7 Access to the day s weather forecast 1 Press the symbol M an d a t o r y internet co n n e c t io n 3 Setting up the Stérilor XP app 24 Stérilor XP Temperature ...

Page 25: ...ration 2 Select My pool 3 Enter the requested information pool information 5 Select My equipment 6 Enter the requested information filtration and slatted cover information 7 Save 4 Save 1 Press the symbol M an d a t o r y internet co n n e c t io n 3 My pool my equipment 3 Setting up the Stérilor XP app 25 Stérilor XP Temperature ...

Page 26: ...e 4 digits indicated on top of the box and Continue 3 Select the device to pair 5 Connected device display 6 Back to the Home page The control box is now paired You are on the Stérilor XP app Home page The Connect must be paired last See the Connect user manual to pair the Stérilor XP Connect M an d a t o r y internet co n n e c t io n 4 Pairing the first control box with the app 4 4 Device Stéril...

Page 27: ...ts indicated on top of the control box and Continue 4 Select the device to pair 6 Connected device display 7 Back to the Home page The Connect must be paired last See the Connect user manual to pair the Stérilor XP Connect The control box is now paired You are on the Stérilor XP app Home page 1 Press the symbol M an d a t o r y internet co n n e c t io n 4 Pairing another control box with the app ...

Page 28: ...or the packaging or enter the serial number indicated next to the QR code When the sensor QR code has been flashed the pool temperature must be entered 1 If this message is displayed press Configure If this message is not displayed the accessory has already been set from the factory with your control box you do not need to flash the QR code 3 Allow the Stérilor app 4 Installed sensor identificatio...

Page 29: ...POOL temperature display WEATHER INFORMATION Enter the exact pool location address 4 Temperature display 4 Device Stérilor XP app installation 29 Stérilor XP Temperature ...

Page 30: ...t relative to the original sensor reading 5 C 7 Wait for about 2 minutes or maybe more depending on the correction difference to update the new temperature value 5 Validate by pressing Measurement complete 2 Read the calibration instructions 4 Press Next and wait a few seconds 6 Follow the instructions and press Finish 2 1 3 5 6 7 4 4 Manual Water temperature calibration 4 Device Stérilor XP app i...

Page 31: ...est with Advanced User rights 2 Select My appliance management 3 Click on the device in question 5 The device is automatically removed from the app 4 Click Remove 1 Press the symbol 5 Removal of a device from the app 5 5 My Stérilor XP account 31 Stérilor XP Temperature ...

Page 32: ...ard the 6 character code to your guest case sensitive Only the owner can invite a user on a pool That user will have 3 access levels Read Only level view of the display no updates allowed User level modification of 1st level parameters Advanced user level access to all functions 1 Press the symbol 5 Invite a user 5 My Stérilor XP account 32 Stérilor XP Temperature ...

Page 33: ...ersonal account on the Stérilor XP app Then follow the steps 2 Select My pools 3 Join a pool 4 Enter the code 6 characters sent by the owner case sensitive How to obtain the code Join a pool see page 32 5 Validate by pressing Join 6 Access to the Home page for the pool in question 1 Press the symbol 5 Join a pool 5 My Stérilor XP account 33 Stérilor XP Temperature ...

Page 34: ... change user access rights on a pool That user will have 3 access levels Read Only level view of the display no updates allowed User level modification of 1st level parameters Advanced user level access to all functions 1 Press the symbol 5 Change a guest s access rights 5 My Stérilor XP account 34 Stérilor XP Temperature ...

Page 35: ...the installation and completed the XP range device configurations they must transfer their rights to the pool owner Only a guest who is already a pool user can access the Owner status For the professional or current owner 1 Press the symbol 5 Transferring management to a new owner 5 My Stérilor XP account 35 Stérilor XP Temperature ...

Page 36: ... owner Only a guest who is already a pool user can access the Owner status For the new owner close and relaunch the Stérilor app 1 Press the symbol 2 Check the owner name 3 Press User management 4 You have access to invite new users 1 2 3 4 Transferring pool management to a new owner continued 5 My Stérilor XP account 36 Stérilor XP Temperature ...

Page 37: ...e same account Private individual max 3 pools Professional unlimited 2 Press My pools 3 Select the pool in question 4 Save 5 The selected pool is displayed 1 Press the symbol 5 Select another pool 5 My Stérilor XP account 37 Stérilor XP Temperature ...

Page 38: ...low steps 1 to 4 To Logout your account follow steps 1 and 2 then 5 and 6 2 Press Manage 3 Modify information 5 Press Logout 4 Save 6 Validate the disconnection 1 Press the symbol 5 Modify or Logout my account 5 My Stérilor XP account 38 Stérilor XP Temperature ...

Page 39: ...Cs General terms and conditions of use Used to access and read all the legal information 5 User manual Access to all the Stérilor XP range user manuals Regular updates to be informed of product changes M an d a t o r y internet co n n e c t io n 6 Legal notices and manuals 6 6 My installation information 39 Stérilor XP Temperature ...

Page 40: ...demo After the demo you will need to access your Stérilor XP account again 5 The Home Page is in demonstration mode You can view the different menus 4 Press Demo mode 6 Press the symbol 8 Validate with OK 9 Open your personal access again 1 Press Information 7 Select Exit Demo To quit Demo mode 6 Demonstration mode 6 My installation information 40 Stérilor XP Temperature ...

Page 41: ...must IMPERATIVELY be removed from the app Once the equipment has been updated you can re pair the Connect The control box concerned by the update downloads the new software The control box LED flashes for a few seconds 2 Select Appliance update 3 Select the device to update 5 Press Close 4 Update progress 1 Press Information 6 Stérilor XP equipment software updates except Connect 6 My installation...

Page 42: ... box 5 Send the code to the Stérilor technician 4 Press Generate a code 1 Press Information 7 Stop the session 2 Select Support access reserved for professionals only 6 View of the Stérilor app on the customer s smartphone on the Stérilor technician s computer Possibility of taking control of the app remotely Possibility of viewing the installation remotely 6 Professional support 6 My installation...

Page 43: ...ws the pool temperature reading variations INFORMATION If equipped with a Stérilor XP Connect the history is continuous possibility of going back to previous dates all the way back to the original installation If not equipped with a Stérilor XP Connect the history goes back 3 days 7 History 7 7 Statuses and anomalies 43 Stérilor XP Temperature ...

Page 44: ... XP Temperature control box The pool water temperature is higher than 15 C and lower than 34 C Your phone is paired to the Temperature control box reading only Indication Smartphone app XP Temperature control box configuration via BLE Control box in factory setting REINITIALISATION mode Program update Colour indicator 1 flash 1 second 3 flashes 1 second Detail The Temperature control box is commun...

Page 45: ...ates that you are nearing the safety temperature that will stop the chlorinator The water is too cold the chlorinator stops producing If the water temperature does not match the value displayed on the app check the sensor connection Reconnect the sensor to the control box Check the sensor condition If necessary replace the sensor possibility of calibrating the sensor refer to the manual To protect...

Page 46: ...ts cable and its connector WINTERING Cut the 6A circuit breaker provided for the Stérilor XP Temperature connection to the filtration control box Clean and rinse the sensor in clean water Store the Temperature sensor in a dry location If the module is installed on a bypass open the central valve and close the others and then drain the vessel 8 Maintenance and wintering 8 8 Maintenance and guarante...

Page 47: ...ailure to comply with product installation instructions Failure to comply with the recommendations in the product manual Damage caused by a non authorised third party Incorrect electric connection or non compliant power source Use for a purpose other than that for which it was designed pool treatment Redox regulation Impacts vandalism or damaged equipment Natural disasters electric overload thunde...

Page 48: ...0 916 979 000034 APE CODE 2223Z FR 314 0091 6979 NextPool All rights reserved 2021 SR 12 288 1 08 2021 AS POOL contact aspool com Phone 33 0 2 43 42 39 20 Fax 33 0 2 43 42 41 53 ZAC de la Rouvelière 72700 SPAY FRANCE 9 9 Contact us 48 Stérilor XP Temperature ...