background image

6

HIGHLIGHTS

The autorange multitester has an interface to connect it to PC and save registries for later 

reading or analysis. 

The screen shows immediately readings.  

It features a soft plastic cover to protect it from light bumps, can measure resistances, diodes, 

capacitors, temperature, AC and DC voltage, AC and DC amperage. 

Perfect for students, technicians and engineers dedicated to repairing, measuring and 

diagnostic of electronic devices.

It includes audible continuity function, luminous screen and data hold.

Light
Autorange
PC connection
Data hold
Audible continuity
Temperature measuring

Summary of Contents for MUL-630

Page 1: ......

Page 2: ...a estar seguro de instalar y poder operar apropiadamente este producto Para apoyo compras y todo lo nuevo que tiene Steren visite nuestro sitio web www steren com MUL 630 Multímetro autorango RMS con interfaz USB La información que se muestra en este manual sirve únicamente como referencia sobre el producto Debido a actualizaciones pueden existir diferencias Por favor consulte nuestra página web w...

Page 3: ...ratorio 11 Rangos de medición 12 Selección de rango 12 Rango manual y Autorango 12 Botón MAX MIN 13 Operación 14 Voltaje de CD Voltaje CA Resistencia Ω Diodos Continuidad Capacitancia Frecuencia Hz Ciclo de trabajo 14 Medición de Temperatura 15 Medición de Corriente A CA A y A CD A 16 Software 17 Especificaciones de medición 18 Especificaciones 23 ...

Page 4: ...conectadas a ningún circuito Para evitar un choque eléctrico o daños al multímetro no lo utilice cerca de sitios mojados Retire las puntas de medición antes de retirar la cubierta Si utiliza este equipo en un ambiente con una fuerte radio frecuencia electromagnética podría influir en la precisión de las mediciones Nunca aplique al medidor voltaje o corriente que exceda las especificaciones máximas...

Page 5: ...Cuando el multímetro esté conectado a circuitos de medición no toque las terminales sin usar Tenga cuidado cuando trabaje con voltajes por arriba de 60Vdc o 30Vac rms Estos voltajes pueden provocar un choque eléctrico Cuando realice conexiones conecte la punta de medición común antes de conectar la punta viva Cuando las desconecte primeramente quite la punta viva y posteriormente la punta común An...

Page 6: ... lo protege de golpes y caídas leves Realiza medición de resistencias diodos capacitoares temperatura voltaje de corriente directa y alterna y amperaje en corriente directa y alterna Ideal para estudiantes técnicos e ingenieros dedicados a la reparación medición y diagnoóstico de equipos electrónicos Incluye también función de continuidad audible iluminación de pantalla y retención de datos Luz Au...

Page 7: ... SÍMBOLOS ELÉCTRICOS INTERNACIONALES Alerta al usuario de presencia de un voltaje peligroso Información de seguridad importante CA Corriente Alterna CD Corriente Directa Tierra Doble aislamiento Fusible ...

Page 8: ...ra voltaje frecuencia ciclo de trabajo resistencia diodo continuidad medición de capacitancia y temperatura 5 Terminal de entrada COM Terminal de retorno para todas las medidas 6 Terminal de entrada μAmA Entrada para 0 1 μA a 600 mA medición de corriente 7 Terminal de entrada 10 A para medición de corrientes altas PARTES ...

Page 9: ...9 ACCESORIOS 1 Multímetro 2 Puntas de prueba 3 Adaptador y termopar 4 Cable USB 1 2 3 4 ...

Page 10: ...LABATERÍA Retire la cubierta protectora Quite los dos tornillos que se encuentran en la parte inferior Remueva la tapa Coloque una batería de 9V poniendo atención a la polaridad Coloque la tapa los tornillos y la cubierta ...

Page 11: ...ición de voltaje CD Voltaje CD milivolts Resistencia Capacitancia Continuidad Diodos Frecuencia Temperatura Corriente microamperes Corriente miliamperes Corriente amperes La tabla siguiente indica la información acerca de las posiciones del interruptor ...

Page 12: ...ue se cambien los puntos de prueba sin tener que restablecer el rango En el modo de rango manual usted debe seleccionar el rango Esto permite anular el autorango y bloquear el medidor en un rango específico El medidor asume por prefijado el modo de medición de autorango Cuando el medidor esta en el modo de autorango AUTO es desplegado Para entrar y salir del modo de rango manual 1 Presione RANGE E...

Page 13: ...lver al modo de medición normal mantenga presionado el botón MAX MIN por dos segundos Bajo la medición de función de ciclo de trabajo y capacitancia solo el modo de autorango está disponible Si usted cambia el rango de medición manualmente después de entrar al modo de REL o HOLD el medidor saldrá de estos modos Mantenga presionada la tecla SELECT mientras enciende el multímetro para deshabilitar l...

Page 14: ...ca el icono correspondiente Para eliminar daños a su persona o daños al medidor por un choque eléctrico por favor no intente medir voltajes arriba de 1000 V Para eliminar daños al medidor o a los dispositivos bajo prueba desconecte la energía del circuito y descargue todos los capacitores de alto voltaje antes de medir resistencia continuidad y capacitancia Para medir alta resistencia 1 MΩ es norm...

Page 15: ...la medición se mostrará en la pantalla El rango de medición de temperatura es 199 a 1000 C Para medir temperatura conecte el medidor como sigue El medidor automáticamente desplegará el valor de la temperatura dentro del medidor cuando no está conectado el probador de temperatura Cuando la medición de temperatura ha sido completada desconecte las puntas de prueba y el circuito bajo prueba y remueva...

Page 16: ...dición se mostrará en la pantalla Por seguridad cada tiempo de medición para alta corriente debe ser al menos de 10 segundos y el intervalo de tiempo entre 2 mediciones debe ser hasta de 15 minutos Cuando la medición de corriente ha sido completada desconecte la conexión entre las puntas de prueba y el circuito bajo prueba y remueva las puntas de prueba de la entrada del medidor ADVERTENCIA Nunca ...

Page 17: ...el cable de comunicación al medidor y el otro extremo a un puerto USB de su computadora 6 Ejecute el programa PC LINK en la PC 7 Seleccione la tasa de sampleo sampling rate en el menú Set y presione Apply 8 Para comenzar a obtener las lecturas use el botón Start 9 Presione Stop para detener y Reset para borrar las lecturas mostradas 10 En el menú File seleccione Save para exportar los datos mostra...

Page 18: ... 2d Rango Resolución Precisión 600 mV 0 1 mV 1 0 de rdg 5d 6V 1 mV 1 0 de rdg 5d 60V 10 mV 1 0 de rdg 5d 600 V 100 mV 1 0 de rdg 5d 1000 V 1 V 1 5 de rdg 5d Voltaje de CA Las precisiones mostradas están garantizadas entre el 5 y el 100 del rango completo La medida rms verdadera tiene un valor dentro de las 10 cuentas cuando las puntas están juntas pero esto no afectará la precisión de la medida ...

Page 19: ...de frecuencias para voltaje CA es 40 400Hz 2 Respuesta para voltaje CA RMS calibrada al rms de la onda sinusoidal 3 Protección de sobrecarga 1000 V CD o 1000V CA rms 4 Impedancia de entrada nominal 10 MΩ Frecuencia Lineal 6HZ 10KHZ Rango Resolución Precisión 99 99 Hz 0 01 Hz 0 05 de rdg 8d 999 9 Hz 0 1 Hz 0 05 de rdg 8d 9 999 kHz 0 001 kHz 0 05 de rdg 8d Las precisiones mostradas están garantizada...

Page 20: ...Ω 1 kΩ 0 5 de rdg 2d 60 00 MΩ 10 kΩ 1 5 de rdg 5d Continuidad Diodos Descripción señal de continuidad 50 Ω Rango Resolución Condición de prueba 600 Ω 0 1 Ω Voltaje de circuito abierto 0 5V aproximadamente Rango Resolución Condición de prueba 3 V 0 001 V Corriente de polarización directa 1mA aproximadamente Voltaje de polarización inversa 1 5V aproximadamente _ ...

Page 21: ...n 6nF 1 pF 5 0 de rdg 30d 60nF 10 pF 5 0 de rdg 20d 600 nF 100 pF 5 0 de rdg 10d 6 μF 1 nF 5 0 de rdg 10d 60 μF 10 nF 5 0 de rdg 10d 600 μF 100 nF 5 0 de rdg 10d 6 mF 1 μF 5 0 de rdg 30d 60 mF 10 μF Sin especificación Rango Resolución Precisión 199 C 0 C 1 C 3 de rdg 5 C 1 C 400 C 1 C 3 de rdg 3 C 401 C 1000 C 1 C 3 de rdg 1 C ...

Page 22: ...CA Rango Resolución Precisión 600 μA 0 1 μA 1 8 de rdg 5d 6000 μA 1 μA 1 8 de rdg 5d 60 mA 0 01 mA 1 8 de rdg 5d 600 mA 0 1mA 1 8 de rdg 5d 6 A 1 mA 3 0 de rdg 8d 10A 10 mA 3 0 de rdg 8d Las precisiones mostradas están garantizadas entre el 5 y el 100 del rango completo La medida rms verdadera tiene un valor dentro de las 10 cuentas cuando las puntas están juntas pero esto no afectará la precisión...

Page 23: ...9 Vcc 1 batería tipo cuadrada Resistencia 0 1 10 kohms 0 5 10k 60 Mohms 1 5 Voltaje CD 0 1 600 mV 0 5 1 1000 V 1 Voltaje CA 0 1 600 mV 1 1 1000 V 1 5 Corriente CD 0 1 μA 10 A 1 5 Corriente CA 0 1 μA 1 A 1 8 1 10 A 3 0 Temperatura 199 C a 1000 C 4 0 Capacitancia 1 pF 60 mF 5 0 Diodos rango 3 V solo rectificadores Frecuencia 1Hz 1MHz 1 Pantalla de LCD 3 5 6 dígitos con indicador de polaridad Tempera...

Page 24: ...iara el consumidor puede recurrir a su proveedor para que le expida otra póliza previa presentación de la nota de compra o factura respectiva DATOS DEL DISTRIBUIDOR Nombre del Distribuidor __________________________ Domicilio ______________________________________ Producto ______________________________________ Marca ________________________________________ Modelo _________________________________...

Page 25: ......

Page 26: ...iew this manual thoroughly to ensure proper installation and operation of this product For support shopping and everything new at Steren visit our website www steren com MUL 630 USB true RMS multitester The instructions of this manual are for reference about the product There may be differences due to updates Please check our web site www steren com to obtain the latest version of the instruction ...

Page 27: ...Measurement ranges 12 Range selection 12 Range manual and auto 12 MAX MIN button 13 Operation 14 Voltage AC DC Diodes Resistance Ω Continuity Capacitance frequency Hz and duty cycle 14 Temperature measurement 15 Measurement of current AC A to and DC A A 16 Software 17 Measurement specifications 18 Specifications 23 ...

Page 28: ...ted to any circuit In order to avoid an electrical shock or damage to the multimeter do not use it in wet areas If this multimeter is used in areas with a high electromagnetic radio frequency this frequency could influence your readings If this multimeter is used near devices that generate a lot of noise the screen might become unstable or indicate errors Do not use the multimeter or the testing p...

Page 29: ...ing the multimeter s function make sure to disconnect the testing points from the circuit being measured Disconnect energy circuits and discharge all high voltage capacitors before making any measurements with the testing points Before measuring current check the multimeter s fuse and remove any energy current from the circuit When making measurements on television you wish to repair make sure to ...

Page 30: ...over to protect it from light bumps can measure resistances diodes capacitors temperature AC and DC voltage AC and DC amperage Perfect for students technicians and engineers dedicated to repairing measuring and diagnostic of electronic devices It includes audible continuity function luminous screen and data hold Light Autorange PC connection Data hold Audible continuity Temperature measuring ...

Page 31: ...7 SYMBOLS Dangerous Voltage may be present Caution AC Alternate Current DC Direct Current Ground Double Isolation Fuse ...

Page 32: ...al Input voltage frequency heavy cycle resistance diode continuity capacitance measurement and temperature 5 COM input terminal Terminal return for all measures 6 Input μAmA terminal Entrance to 0 1 μA to 600 mA measuring current 7 10 A input terminal for high current measurement PARTS ...

Page 33: ...9 ACCESSORIES 1 Multimeter 2 Test probes 3 Thermocouple and adapter 4 USB cable 1 2 3 4 ...

Page 34: ...0 INSTALL REPLACE THE BATTERY Remove the protective cover Remove the two screws located at the bottom Remove the battery lid Place a 9V battery paying attention to polarity Place the cover screws and lid ...

Page 35: ...ge DC Voltage DC Voltage milivolts Resistance Capacitance Continuity Diode Frequency Temperature Current microamperes Current miliamperes Current amperes The following table indicates the information about the switch positions ...

Page 36: ...ws test points to be changed without having to reset the measurement At the manual range mode you must select the range This allows you to override the autorange and lock the meter in a specific range The meter assumes by default the autoranging measurement mode When is the meter is in the autorange AUTO mode displayed To enter and exit the manual range mode 1 RANGE The meter enters the manual ran...

Page 37: ...ain to display the minimum To return to the normal measurement mode hold the MAX MIN button for two seconds If you change the measuring range manually after you enter the REL HOLD the meter exits these modes Under the function of cycle frequency and capacitance measurement only autorange mode is available Press and hold SELECT key while turning on the meter to disable autopower off ...

Page 38: ...button until the corresponding icon Do to eliminate damage to the person or to the meter due to electrical shock please not attempt to measure voltages above 1000 V To eliminate damage to the meter or to the devices under test disconnect circuit power and discharge all high voltage capacitors before testing resistance continuity and capacitance For measuring high resistance 1 MΩ is normal for the ...

Page 39: ...e value of the measurement is displayed on the screen Temperature measurement range 199 to 1000 C To measure temperature connect the meter as follows The meter will automatically display the value of the temperature inside the meter when thermocouple is not connected When temperature measurement has been completed disconnect the thermocouple and the circuit under test and remove the adaptor of the...

Page 40: ...o the circuit 7 The value of the measurement is displayed on the screen For safety each measuring time for high current must be at least 10 seconds and the time interval between 2 measurements should be up to 15 minutes When the current measurement has been completed disconnect the connection between the test leads and the circuit under test and remove the probes of the meter input Warning Never a...

Page 41: ...5 Connect the optical end of the communication cable to the meter and the other end to a USB port on your computer 6 Run the program PC LINK on the PC 7 Select the sampling rate in the Set menu and press Apply 8 To begin the readings use the Start button 9 Press Stop to stop and Reset to clear the displayed readings 10 In the File menu select Save to export the data displayed one Excel xls or text...

Page 42: ... 0 de rdg 2d Range Resolution Accuracy 600 mV 0 1 mV 1 0 de rdg 5d 6V 1 mV 1 0 de rdg 5d 60V 10 mV 1 0 de rdg 5d 600 V 100 mV 1 0 de rdg 5d 1000 V 1 V 1 5 de rdg 5d Voltage AC Above accuracies can be guaranteed within 5 100 of the full range The true RMS meter has residual value within 10 counts when the test leads are shorten but that will not affect the accuracy of measurement ...

Page 43: ...g 3d 1 Frecuency range for ACV 40Hz 400Hz 2 Response for ACV RMS calibrated in rms of sine wave 3 Overload protection 1000 V DC or 1000V AC rms 4 Input impedance nominal DC voltage 10 MΩ AC voltage 10 MΩ Linear Frequency 6HZ 10KHZ Range Resolution Accuracy 99 99 Hz 0 01 Hz 0 05 de rdg 8d 999 9 Hz 0 1 Hz 0 05 de rdg 8d 9 999 kHz 0 001 kHz 0 05 de rdg 8d Above accuaries can be guarantted within 10 1...

Page 44: ...kΩ 100 Ω 0 5 de rdg 2d 6 000 MΩ 1 kΩ 0 5 de rdg 2d 60 00 MΩ 10 kΩ 1 5 de rdg 5d Continuity Diode Description Continuity beeper 50 Ω Range Resolution Test condition 600 Ω 0 1 Ω Open circuit voltage approx 0 5V Range Resolution Test condition 3 V 0 001 V Forward DC current approximately 1mA Reversed DC voltage approximately 1 5V _ ...

Page 45: ... μF 1 nF 5 0 de rdg 10d 60 μF 10 nF 5 0 de rdg 10d 600 μF 100 nF 5 0 de rdg 10d 6 mF 1 μF 5 0 de rdg 30d 60 mF 10 μF unspecification Temperature Range Resolution Accuracy 199 C 0 C 1 C 3 de rdg 5 C 1 C 400 C 1 C 3 de rdg 3 C 401 C 1000 C 1 C 3 de rdg 1 C The specifications of temperature don t include thermocouple errors ...

Page 46: ...Current ACA Range Resolution Accuracy 600 μA 0 1 μA 1 8 de rdg 5d 6000 μA 1 μA 1 8 de rdg 5d 60 mA 0 01 mA 1 8 de rdg 5d 600 mA 0 1mA 1 8 de rdg 5d 6 A 1 mA 3 0 de rdg 8d 10A 10 mA 3 0 de rdg 8d Above accuracies can be guaranteed within 5 100 of the full range The true RMS meter has residual value within 10 counts when the test leads are shorten but that will not affect the accuracy of measurement...

Page 47: ...ON to measure 10 minutes OFF above 10 A unspecified Input 9 Vcc 1 square battery Resistance 0 1 10 kohms 0 5 10k 60 Mohms 1 5 DC voltage 0 1 600 mV 0 5 1 1000 V 1 AC voltage 0 1 600 mV 1 1 1000 V 1 5 DC current 0 1 μA 10 A 1 5 AC current 0 1 μA 1 A 1 8 1 10 A 3 0 Temperature 199 C to 1000 C 4 0 Capacitance 1 pF 60mF 5 0 Range diodes 3V only rectifiers Frequency 1Hz 1MHz 1 LCD screen 3 5 6 digits p...

Page 48: ...consumables and accessories to customer as well as warranty service at any of the addresses mentioned later THIS WARRANTY IS VOID IN THE NEXT CASES If the product has been damaged by an accident acts of God mishandling leaky batteries failure to follow enclosed instructions improper repair by unauthorized personnel improper safe keeping among others a The consumer can also claim the warranty servi...

Page 49: ......

Page 50: ...Centro de Servicio a Clientes Customer Service Center Este instructivo puede mejorar con su ayuda llámenos Help us to improve this instruction manual call us www steren com 01800 500 9000 ...