3 Overview of Functions
Power Switch
Mini USB Port
Navigator A
Navigator B
Run/Hold
Select
Save Screen
Save Conf.
Test Port
3" TFT LCD
SARK-110
é
•••
ê
-
•••
+
Ø
||
USB
ON
Test
Port
The unit has a Test Port located on the left side to connect to the device under test. This receptacle
accepts straight MCX plug connector types. The product pack includes a MCX plug to BNC female
cable adapter.
The USB port located on the right side allows connecting the unit to a personal computer for
communication and internal battery charging using a compatible mini-USB cable (not included). The
unit charges the internal battery when connected to USB. The internal battery charger manages
automatically the charge cycle and stops the process when battery is fully charged. The complete
charge cycle takes around 3.5 hours.
Slide the Power Switch button located on the right side to the ON position for turning on the unit. An
automatic power-off feature can be set for power-saving after a user specified period of inactivity.
Operation is controlled by four buttons and two navigation keys located on the top side of the unit. A
3” TFT color LCD is used for display diagrams.
Summary of Contents for SARK-110
Page 25: ...SteppIR SARK 110 User s Manual Rev 1 1 7 October 29th 2014 25 Melchor Varela EA4FRB 2011 2014 ...
Page 49: ...SteppIR SARK 110 User s Manual Rev 1 1 7 October 29th 2014 49 Melchor Varela EA4FRB 2011 2014 ...
Page 55: ...SteppIR SARK 110 User s Manual Rev 1 1 7 October 29th 2014 55 Melchor Varela EA4FRB 2011 2014 ...
Page 64: ...SteppIR SARK 110 User s Manual Rev 1 1 7 October 29th 2014 64 Melchor Varela EA4FRB 2011 2014 ...