![SteppIR SARK-110 User Manual Download Page 57](http://html.mh-extra.com/html/steppir/sark-110/sark-110_user-manual_1372706057.webp)
SteppIR
SARK-110
User’s Manual
Rev 1.1.7 October 29
th
, 2014
- 57 -
© Melchor Varela – EA4FRB 2011-2014
Cable Test Mode
Maximum length: about 250 m
Displays step and impulse responses
Field Mode
Graphical plot of one user-selected parameter in a scalar chart with
enhanced legibility
Display max and min values
Multi-band Mode
Display rectangular charts for four bands simultaneously
Signal Generator
Mode
Precise RF signal generator with 1 Hz resolution
Programmable output level from -73 dBm to -10 dBm
Continuous and frequency sweep modes
Linear, logarithmic, bi-linear, and bi-logarithmic sweep modes
Markers
Tracking modes:
o
Peak Min
o
Peak Max
o
Absolute Min
o
Absolute Max
o
Value Cross Any
o
Value Cross Up
o
Value Cross Down
Interface
Full color 3” TFT LCD 400 x 240
4 dedicated buttons
2 navigation keys
MCX antenna socket
PC Interface
USB Mini-B receptacle
USB 2.0 Full Speed
USB Composite Device:
o
Mass Storage Class (internal disk)
o
HID Class (Computer Control mode)
Storage
2 MB internal disk FAT compatible
USB Mass Storage
Screenshot save and recall feature
Summary of Contents for SARK-110
Page 25: ...SteppIR SARK 110 User s Manual Rev 1 1 7 October 29th 2014 25 Melchor Varela EA4FRB 2011 2014 ...
Page 49: ...SteppIR SARK 110 User s Manual Rev 1 1 7 October 29th 2014 49 Melchor Varela EA4FRB 2011 2014 ...
Page 55: ...SteppIR SARK 110 User s Manual Rev 1 1 7 October 29th 2014 55 Melchor Varela EA4FRB 2011 2014 ...
Page 64: ...SteppIR SARK 110 User s Manual Rev 1 1 7 October 29th 2014 64 Melchor Varela EA4FRB 2011 2014 ...