12
© Guldmann GB/US-1412/01/18 • # 30901020
© Guldmann GB/US-1412/01/18 • # 30901020
Heating cable .
Lifting platforms installed outdoors are normally fitted with a
heating cable of 220 Watt. This should be left on whenever there is a danger
of frost.
The following points must be adhered to:
• There is a risk of getting jammed at the moving parts of the platform, for
instance the automatic doors.
• Fingers must not be placed in the gaps in the lifting platform’s columns/tower
as this can lead to them being crushed.
• Parts and components must not be removed from the lifting platform.
• Contact the supplier in the event of faults or defective components. Use only
original spare parts.
• The control panel must not be covered.
• Signs must not be removed or covered.
• Great care must be taken in the winter because of the risk of slipping on the
lifting platforms floor and access ramp.
• Great care must be taken when using the emergency lowering device.
6 .00
Maintenance
Exercise caution while working beneath the platform, as a crush hazard may
arise between the platform’s moving parts.
Important!
A blocking beam must always be used while working beneath the
platform.
The following safety advice must be adhered to:
• Run the platform all the way to the upper level.
• Next, disconnect the platform’s power source in
order to prevent the risk of electrical shock and
crushing.
• Insert the blocking beam beneath the platform
beside the left post, as shown in the drawing. It
is now safe to work beneath the platform.
• The lifting platform may NOT be raised/lowered
while work is being performed beneath the
platform. This rule applies even if the blocking
beam or other safety devices are in place.
• Only one person is allowed to work on the lifting platform once it has been
installed, connected and can be raised/lowered.