General Information
43
9.
Install new coil over rotor on the remaining amber
bracket. The correct orientation is with two copper
rods in the upper right corner and the vent opening at
the bottom of the motor housing. Place bracket back
on the rotor and securely seat into new coil. Install
screws and washers and fasten bracket to coil.
10.
With the metal band facing the bracket, press fan
flush on rotor shaft.
Continued...
11.
With wire strippers set at 16 gauge, strip approximately
1/2" from the power cord and on/off switch lead wires in the
motor housing.
12.
Secure ground wire (with eyelet) to motor coil.