9
USA and Canada 800.683.2378, International 904.641.1666
Stennicator
FLOW RATE OUTPUT
NOTICE:
The information within this chart is solely intended for use as a guide. The output data is an approximation based on
pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump
Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
FLOW RATE OUTPUT
Item
Number Prefix
Pump
Tube
Roller
Ounce
Pressure
Milliliters
Pressure
Assembly
per Minute
Max. psi
per Minute
Max. bar
E20MH
H
Black
2.7
80
74.0
5.5
Approximate Maximum Outputs @ 50/60Hz
NOTE: Duckbill check valve included with pumps rated 80 psi (5.5 bar) maximum.
Setting
Run Time
*
in seconds
Simplex
Duplex
PRIME
60
60
1 PPG
22
11
1 PPL
6
3
10 PPG
2
1
*
Times are approximate (in seconds).
Key
PPG
pulse per gallon
**
PPL
pulse per liter
**
10 PPG is often referred to as 0.1 US gallons per pulse