background image

2

Please read and make sure you understand all instructions and safety warnings. Electrical 

 cables, if not installed correctly or are damaged, can cause a fire, shock and arcing hazard.
1.  Installation must be in compliance with National Electrical Codes (NEC) and the Canadian 

Electrical Code (CEC).

2.  Use 30-mA ground fault protection (GFCI) on each heating cable branch circuit for maximum 

protection.

3.  Use only fire-resistant insulation, such as fiberglass or preformed foam. Do not embed heating 

cable in the insulation.

4.  Use fiberglass or aluminum adhesive foil tape when attaching cable to pipe. Do not use wire or 

metal clamps.

5.  Before installing or servicing, disconnect power at service panel.
6.  Do not twist cable during installation.
7.  Do not install this heating cable under roofing material.
8.  Do not expose this heating cable to temperatures above 185°F (85°C), as this will damage the 

cable.

9.  Do not use extension cords.

IMPORTANT INSTRUCTIONS

WARNING: Do not use damaged heating cables, power cord or plug. 
 Remove and replace immediately to prevent a fire, shock or arcing hazard

SAVE THESE INSTRUCTIONS

NOTE: Accessories are sold separately.

INSTALLATION 

PIPE

ACCESSORIES REQUIRED

SSFR-ALUTAPE

Aluminum adhesive foil tape

Insulation

Summary of Contents for SSFP Series

Page 1: ...I T C ERTIFI REGISTERED Q U A L I T Y S Y S T E M WWW STELPRO COM 1 844 STELPRO SSFP SELF REGULATING FREEZE PROTECTION PREASSEMBLED CABLE THANK YOU FOR YOUR PURCHASE NEED ASSISTANCE CONTACT STELPRO S...

Page 2: ...4 Use fiberglass or aluminum adhesive foil tape when attaching cable to pipe Do not use wire or metal clamps 5 Before installing or servicing disconnect power at service panel 6 Do not twist cable dur...

Page 3: ...E E E F F G G G G G H H H H H I I J J J Plastic B C E F F G G G H H H I I J J 2 Metal A B C D E E E F F G G G G G H H H H I I I J J J Plastic B D E F G G G H H I I J J PRODUCT LENGTH VOLTAGE CODE FT...

Page 4: ...metallic products or wire On plastic pipes secure the full length of cable with aluminum foil tape SSFR ALUTAPE 2 ATTACHING CABLE TO PIPE 1 Before insulating inspect the cable to make sure that it is...

Page 5: ...FR14 x50 Roof clips for SSFP SSFR cables SSFR15 Downspout cable hanger bracket for SSFP SSFR cables Ties For shingle roof NOTE Accessories are sold separately Putty Knife Marking chalk Weighted String...

Page 6: ...ngth of the downspout to determine the length of cable needed 5 For roof valleys measure the distance two thirds of the way up and double it Add this additional length to the overall cable length EXAM...

Page 7: ...Use a downspout cable hanger bracket SSFR15 to support the heating cable where it enters a downspout to prevent cable from being damaged by the gutter s edge It also can be used as a spacer in wider g...

Page 8: ...damages penalties special or punitive damages damages for lost profits loss of use of equipment cost of capital cost of substitute products facilities or services shutdowns slowdowns or for other type...