7

INSSEFECMI0513

Ventilation continue / Continuous ventilation

Chauffage continu / Continuous Heat

Demande de chauffage / Heating demand

Haute vitesse

High speed

Basse vitesse

Low speed

2,5kW

5kW

Puissance

Power

50%

100%

COM1

Electronic 

control board

Auxiliary connections

to electronic control board

Electric Furnace

NO1

NC1 NO2

NC2

COM2

R

C

Y

G

W1 W2

THERMOSTAT connections 

to electronic control board

O/B

120Vac

Auxiliary device connections 

with internal 24V, 

on contacts #1 and #2

24 Vac

or

12 VDC

Control Relay supplied by other

Terminal R: 1A maximum

Contact #1 or #2:

2A, 24 VAC maximum

600mA, 12 VDC maximum

1 Control relay 

24V Coil

1 Control relay 

24V Coil

Auxiliary device connections 

with external 24V, 

on contacts #1 and #2

ConTroL PAneL

1. 

Low sPeeD ConTinuous VenTiLATion

 button: provides the  

 

selection of the low speed continuous ventilation mode.

2. 

Low sPeeD ConTinuous VenTiLATion

 pilot light: indicates  

 

that the low speed continuous ventilation mode is activated.

3. 

high sPeeD ConTinuous VenTiLATion

 button: provides the  

 

selection of the high speed continuous ventilation mode.

4. 

high sPeeD ConTinuous VenTiLATion

 pilot light: indicates  

 

that the high speed continuous ventilation mode is activated.

5. 

2.5 kw ConTinuous heATing

 button: provides the selection of  

 

the 2.5 kW continuous heating mode.

6. 

2.5 kw ConTinuous heATing

 pilot light: indicates that the    

 

2.5 kW continuous heating mode is activated. This mode  

 

 

is pending if the pilot light is blinking (see CONTINUOUS  

 

 

HEATING section on following page).

7. 

5 kw ConTinuous heATing

 button: provides the selection of  

 

the 5 kW continuous heating mode.

8. 

5 kw ConTinuous heATing

 pilot light: indicates that the 5 kW  

 

continuous heating mode is activated. This mode is pending if the  

 

pilot light is blinking (see CONTINuOuS HEATING    

 

 

section on following page).

9. 

ThermosTAT

 pilot light: indicates that the furnace is receiving a  

 

heating demand from the thermostat.

10. 50% or 100% 

heATing CAPACiTY

 buttons: allow to choose the  

 

heating capacity of the furnace in case of a heating demand from  

 

the thermostat. Two possible capacities: 50% or 100%.

11. 50% pilot light: indicates that the selected heating capacity is 50%.
12. 100% pilot light: indicates that the selected heating capacity is 100%.

LÉgenD

A humidifier and an electronic filter can be 

controlled directly from the furnace. There 

is a terminal block for this purpose on the 

control card. The terminal block is equipped 

with six terminals connected to two DPDT 

that allow to switch the command of the 

auxiliary devices when the blower of the 

furnace is in operation.

electrical connection of an electronic filter and a humidifier

* R terminal : 600mA maximum

TYPICAL FuRNACE TO AuxILIARY DEVICE CONNECTIONS

heATing DemAnD wiThouT PLenum 

TemPerATure sensor

one-sTAge ThermosTAT

1. The  thermostat  closes  the  R-W1  circuit,  which  activates  the  first 

stage of the heating sequence. The blower starts-up at low speed and 

half of the furnace elements are activated one by one.

2. If the heating capacity selector is set at 50%, the sequence is ended 

and only half of the furnace capacity is used. However, if the selector 

is set at 100%, the sequence continue as follows:
3. The blower switches to heating speed and the remaining furnace 

elements are activated one by one.

operation

Summary of Contents for SEFECM Series

Page 1: ...r further information or to consult this guide online please visit our website at www stelpro com This unit complies with CSA and UL standards This unit is approved according to the Canadian and Ameri...

Page 2: ...ouch hot surfaces Let the unit cool down for a few minutes before handling it it stays warm for some time after shut down Never block air vents This obstruction could lead to overheating which could r...

Page 3: ...tion Location You must install the furnace on a dry and solid base in an area free of flammable liquids or vapors and combustible materials You must indicate to the furnace user the location of the sw...

Page 4: ...e between 40 C 104 F and 70 C 158 F Optional accessories The furnace is equipped with all the devices required for the addition of an air conditioner or a heat pump except the heat cool thermostat The...

Page 5: ...rnace at 208 VAC you must change a connection on the 24 V terminal board of the transformer see the illustration below Refer to the local and national electrical codes to know which wire size fuses an...

Page 6: ...t or heat of the sun a lamp a fireplace or any other heat source close or in front of an air outlet close to concealed ducts or a chimney and in a location with poor air flow e g behind a door or with...

Page 7: ...EATING button provides the selection of the 5 kW continuous heating mode 8 5 kW CONTINUOUS HEATING pilot light indicates that the 5 kW continuous heating mode is activated This mode is pending if the...

Page 8: ...tivate the 100 capacity Continuous ventilation Two ventilation speeds can be selected on the furnace control panel Low speed continuous ventilation or High speed continuous ventilation If the pilot li...

Page 9: ...r conditioning A potentiometer allowing to adjust the airflow corresponds to each of these five modes The potentiometers are located in front of the furnace electrical panel The adjustment scales of t...

Page 10: ...at is set off This means that there is a risk of electric shock as long as the unit is energized Preventive maintenance Do not try to repair your furnace yourself Call a qualified technician However b...

Page 11: ...the unit capacity Faulty relay Control card autodiagnostic The control card of the furnace is equipped with three LED pilot lights that allow easy and quick diagnostic of its essential functions They...

Page 12: ...SEFECM2021 9 CIR 003 SEFECM2321 MAIN CONTROL CARD SEFECM2321 9 CIR 003 SEFECM2721 MAIN CONTROL CARD SEFECM2721 9 CIR 003 SEFECM3021 MAIN CONTROL CARD SEFECM3021 10 CIR 005 SEFECM1021 CONTROL CIRCUIT B...

Page 13: ...y for property or personal injury damages penalties special or punitive damages damages for lost profits loss of use of equipment cost of capital cost of substitute products facilities or services shu...

Page 14: ......

Reviews: