Page 21
16400-7801 GST REV F
Figure 7
&$87,21&RQVXOWWKHORFDODQGQDWLRQDOLQVWDOODWLRQFRGHVWRDVVXUHDGHTXDWHFRPEXVWLRQDQGYHQWLODWLRQDLULVDYDLODEOH
127()ODPHKHLJKWDQGDSSHDUDQFHZLOOYDU\GHSHQGLQJXSRQYHQWLQJFRQ¿JXUDWLRQDQGW\SHRIIXHOXVHG
9HQWLQJUHTXLUHPHQWVDSSO\WRERWK1DWXUDODQG3URSDQHJDV
STOP: MAINTAIN ALL CLEARANCES AS STATED IN THIS INSTALLATION MANUAL.
8 - VENTING
A. APPROVED VENTING
Model #
DESCRIPTION
B-VENT
OUTSIDE
AIR
STANDARD
POWERVENT
IN-LINE
POWERVENTV
3-ST-X-GL
X = ANY HEIGHT
8"
10"
RS012
RSIF160
4-ST-X-GL
X = ANY HEIGHT
8”
10”
RS012
RSIF160
5-ST-X-GL
X = ANY HEIGHT
8”
10”
RS012
RSIF160
6-ST-X-GL
X = ANY HEIGHT
10”
10”
RS014
RSIF180
7-ST-X-GL
X = ANY HEIGHT
10”
10”
RS014
RSIF180
8-ST-X-GL
X = ANY HEIGHT
10"
12"
RS014
RSIF180
B. POWERVENT SUPPLY VOLTAGE
POWERVENT MODEL NUMBER
VAC
AMP
H/P
RS012 (3', 4', & 5' Models)
120
1.2
1/9
RS014 (6', 7' & 8' Models)
120
1.4
1/7
RSIF160 (3', 4', & 5' Models)
120
2.9
3/7
RSIF180 (6', 7' & 8' Models)
120
5.3
13/16
C. SYSTEM SUPPLY VOLTAGE
POWERVENT MODEL NUMBER
VAC
AMPS
RS012 (3', 4', & 5' Models)
120
3.2
RS014 (6', 7' & 8' Models)
120
3.4
RSIF160 (3', 4', & 5' Models)
120
4.9
RSIF180 (6', 7' & 8' Models)
120
7.3
Figure 8A
*Amperage listed is the maximum required for the appliance with all options.
Refer to the vent systems manufacturer's installation manual for complete installation instructions.
Installation must conform with the venting requirements and restrictions as outlined in this manual.
SEE CHART ABOVE FOR SIZE diameter B-Type Venting that must be used. UL/CSA approved
B-Vent only. DO NOT decrease the vent size.
Vent runs are approved for up to 110 feet with quantity of eleven 90 degree elbows.
9HQWUXQVPD\DOVRFRQWDLQDGRZQZDUGFRPSRQHQW
The downward component may
be a maximum of 6 feet plus the distance to the center line of the elbow. See Figure 8A.1.
This will be about 87" for 8" diameter pipe and 92" for 10" diameter pipe.
'XHWRQDWXUDOEXR\DQF\RIÀXHJDVSURGXFWVYHQWLQJGRZQZDUGLQFUHDVHVUHVWULFWLRQ
(YHU\LQFKRIYHUWLFDOGURSFRXQWVDVWULSOHLQFKHVVXEWUDFWHGRႇWKHWRWDOYHQWUXQ
Example: a maximum drop of 92" means the total allowed vent run is decreased by 276" (23')
Once a downward component has been utilized, the vent cannot go upwards again,
Moisture may get trapped in the vent pipe.
Important: Be sure to do your own calculations based on the center line dimension
given from the pipe manufacture you are using for your installation.
127($OOSLSHDQGHOERZMRLQWVPXVWEHVHDOHG7KLVLQFOXGHVWKHORQJLWXGLQDOVHDPRQWKHSLSH
+LJK7HPS5796LOLFRQHDQGRUIRLOWDSH0867EHXVHGRQHDFKMRLQWVHDP
)DLOXUHWRGRVRPD\FDXVHODFNRIYDFXXPDQGPD\QRWWULJJHUWKHYDFXXPVZLWFK