Page 11
16400-7801 GST REV F
63(&,),&$7,216
F. CLEARANCES
From unit left & right sides
1"
25mm
7RÀRRULQJXQGHU¿UHSODFH
0
0
Unit top to ceiling
6"
152mm
Unit side to adjacent sidewall
1"
25mm
X3 1/2” [13] Hood Standoffs
Refer to Section 5 (Non-Combustible Zone)
for more information.
CLEARANCES SHOWN ARE MINIMUM TO COMBUSTIBLES
NON-COMBUSTIBLE FRAMING AND FINISHING MATERIALS ALLOWED RIGHT UP TO THE FIREPLACE.
X4 6” [152] Top Standoffs; shipped flat.
Refer to Section 3 (Prepare The Fireplace)
for assembly instructions.
X4 6” [152]
Top Standoffs
Minimum distance recommended
from front of appliance for service access.
1/2” [13]
1/2” [13]
1”
[25]
24” [610]
1”
[25]
6”
[152]
1”
[25]
NO COMBUSTIBLE
FRAMING MATERIALS
WITHIN 1” [25] OF THE
SIDES AND BACK OF THE
FIREPLACE.
This does not include
finishing materials or
perpendicular wall intended
to cover the face/trim.
Combustible Framing
Can be a recess and/or combustible perpendicular wall extending
past the face of the fireplace.
Refer to Section 3
(Specifications - See Through Dimensions)
for more measurements.
1/2” [13]
OTHER CLEARANCE NOTES:
No combustible material within 6” [152] of the top of the fireplace.
No combustible material within 1 [25] around the B-Vent flue.
Combustible finishing materials may cover the 3” [76] top and bottom black trim. Do not overlap glass.
Combustible framing allowed right up to the fireplace below the viewing area only.
A combustible mantel may be placed at the top of the viewing area. Do not overlap glass.
A combustible hearth extension may be used below the viewing area. Do not overlap glass.
Do not place on carpet, vinyl or soft surfaces.
Top Black Trim
Bottom
Black Trim
1”
[25]
)LJXUH)