INS_RENEW INS Rev E
Page 49
22 - NG to LP CONVERSION KIT INSTRUCTIONS
1. Turn on the gas and electricity to the fireplace. Light the pilot by pressing the "Pilot" button. CONSTANT PILOT will
appear on the LCD screen (Figure 17J). The pilot should light.
2. Using a solution of soapy water, check the pilot tube and nut area for leaks.
3. If no leaks are present, extinguish the pilot and proceed.
1. Loosen inlet ("IN") pressure tap screw (counter-clockwise).
2. Attach manometer using a 1/4" I.D. hose.
3. Light fireplace using hand held remote control.
Note manometer reading.
4. Turn fireplace off using hand held remote control.
5. Disconnect hose and tighten screw (clockwise).
Screw should not be over-tightened.
6. Re-light fireplace using hand-held remote
control. Re-attach manometer to inlet pressure
tap to verify that it is completely sealed.
Manometer should read no pressure.
Figure 22G
WARNING
A LOW PRESSURE READING CAN CAUSE DELAYED IGNITION.
IMPORTANT NOTE
If inlet pressure reading is too high or too low, contact the gas company. Only a qualified gas service technician should
adjust the incoming gas pressure.
IMPORTANT NOTE
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure
testing of that system at pressures in excess of 1/2 psi. The appliance must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure testing of the gas line at test pressures equal to or less
than 1/2 psi (3.5 kPa).
IMPORTANT NOTE
Pressure check taps for the manifold (outgoing) and inlet (incoming) pressure have been incorporated into the valve. The
pressure tap marked “OUT” measures outgoing pressure and the pressure tap marked “IN” measures incoming pressure.
Follow instructions below for proper testing procedures.
IMPORTANT NOTE
When the fireplace is initially lit, condensation will appear on the glass; this is normal in all places and will disappear after
several seconds.
IMPORTANT NOTE
If the fireplace will not operate, follow the instructions TURNING OFF GAS TO FIREPLACE and call your service technician
or the gas supplier.
F. TESTING FOR LEAKS:
G. INLET PRESSURE TEST:
Inlet Pressure Screw