![Stel TIG 303 Instruction Manual Download Page 35](http://html1.mh-extra.com/html/stel/tig-303/tig-303_instruction-manual_1371521035.webp)
6943200010
35
THREE-PHASE CONNECTION
To connect the generator to a standard three-phase socket, follow the diagram below:
SINGLE PHASE CONNECTION (boost power source)
This unit can be connected to the 230V single-phase network without having to open it to redo connections. To do
this, follow the diagram below:
INPUT POWER
CABLE
CE COLOUR
CSA COLOUR
CONNECTION
L1
black
Black
To 3-phase plug
L2
grey
white
To 3-phase plug
L3
brown
red
To 3-phase plug
GND/PE
Green/yellow
green
To earth/gnd
INPUT POWER
CABLE
CE COLOUR
CSA COLOUR
CONNECTION
L1
black
Black
To 1-phase plug
L2
grey
white
To 1-phase plug
L3
brown
red
Not connected
Isolated.
GND/PE
Green/yellow
green
To earth/gnd
Summary of Contents for TIG 303
Page 27: ...6943200010 27 WIRING DIAGRAM TIG 303 453 AC DC...
Page 28: ...6943200010 28 WIRING DIAGRAM TIG 453S AC DC...
Page 29: ...6943200010 29 EXPLODED VIEW TIG 303 453 AC DC...
Page 31: ...6943200010 31 EXPLODED VIEW TIG 453 S AC DC...
Page 36: ...6943200010 36 Info www stelgroup it tel 39 0444 639525...