MAINTENANCE
7.3
7.3
7.3
7.3 ---- ROUTINE MAINTENANCE
ROUTINE MAINTENANCE
ROUTINE MAINTENANCE
ROUTINE MAINTENANCE
ATTENTION!!
Maintenance operations to be performed only by qualified personel.
The lasting efficiency of the welding system is directly linked with the frequency of
maintenance operations, in particular:
For welding machines, it is sufficient to keep the inside clean; the dustier the working
environment, the more frequently the inside should be cleaned.
- Remove the cover.
- Remove every trace of dust from the internal parts of the generator using a jet of compressed
air with pressure not higher than 3 Kg/cm2 (0,3 M Pa).
- Check all the electrical connections, ensuring that screws and nuts are firmly secured.
- Do not hesitate to replace worn components.
It is obligatory to apply silicone on the Gasket when refitting the cover
Silicon type: SISTA SILICON 5 UNIVERSAL
- Replace the cover.
- Once the above operations have been completed, the generator is ready for service,
following the instructions given in the chapters on “system installation”.
CLEANING THE DUST FILTERS
CLEANING THE DUST FILTERS
CLEANING THE DUST FILTERS
CLEANING THE DUST FILTERS
IT IS NECESSARY TO CLEAN THE REAR, SIDE AND FRONT DUST FILTERS
PERIODICALLY USING A JET OF COMPRESSED AIR.
BEFORE ALL OPERATIONS, DISCONNECT THE MACHINE
FROM THE PRIMARY SUPPLY MAINS