MAX 171 ATX
COD. 6928900000
CONNECTION
- Before making the electrical connections between the current generator and the line switch,
ensure that the switch is turned off .
- The distribution panel must comply with the regulations in force in the country of use
- The mains system must be of the industrial type.
- The multicore cable is provided with a plug type CEE 3P + T in accordance with standard.
- Make absolutely sure that the socket is of a suitable type with block switch.
- For longer connecting cables, increase the lead section as required.
- Upstream, the mains socket must have a suitable switch provided with delayed fuses.
(*)
(*)
(*)
(*) ATTENTION: 4 POLE FOR SAFETY OF POWER
ATTENTION: 4 POLE FOR SAFETY OF POWER
ATTENTION: 4 POLE FOR SAFETY OF POWER
ATTENTION: 4 POLE FOR SAFETY OF POWER
SUPPLY PANELS
SUPPLY PANELS
SUPPLY PANELS
SUPPLY PANELS
ATTENTION:
The security protection for the Red Emergency button ( ref. 12 cap.4.1) on the
front panel is active only if the 4th secuirty core of the supply cable is
correctly connected.
The plug and the socket must be of the type as specified in the diagram at
Cap. 10.3.
MODEL
VOLTAGE/PHASES
DELAYED FUSE
MAX 171 ATX
230V 1 PHASES (*)
16 A
3.4
3.4
3.4
3.4 ---- PRIMARY CONNECTION
PRIMARY CONNECTION
PRIMARY CONNECTION
PRIMARY CONNECTION
INSTALLATION
The good operation of the generator is ensured by correct installation; you must therefore
proceed as follows:
- Position the machine in such a way that there is no obstacle to the air circulation ensured by
the internal fan (the internal components require suitable cooling) (see chap. 6.4).
- Ensure that the fan does not send deposits or dust into the machine.
- Avoid impacts, rubbing, and - absolutely - exposure to dripping water, excessive heat
sources, or any abnormal situations.
MAINS VOLTAGE
The MAX 171ATX generator works for mains voltages that differ by 15% from the rated mains
value of 230V (Minimum voltage 195V, maximum voltage 265V).
TECHNICAL
DESCRIPTION
ENGLISH