INSTALLATION
WARNING
This
Class A
equipment is not intended for use in
residential locations where the electrical power is
provided by the public low-voltage supply system.
There may be potential difficulties in ensuring
electromagnetic compatibility in those locations,
due to conducted as well as radiated disturbances.
This equipment does not comply with
IEC 61000-
3-12
. If it is connected to a public low voltage
system, it is the responsibility of the installer or
user of the equipment to ensure, by consultation
with the distribution network operator if necessary,
that the equipment may be connected.
The good operation of the generator is ensured by
correct installation; you must therefore proceed as
follows:
- Position the machine in such a way that there is
no obstacle to the air circulation ensured by the
internal fan since the internal components require
suitable cooling.
- Ensure that the fan does not send deposits or
dust into the machine.
- Avoid impacts, rubbing, and - absolutely -
exposure to dripping water, excessive heat
sources, or any abnormal situations.
MAINS VOLTAGE
The generator works at mains voltages differing by
20% from the rated mains (400V rated, Minimum
voltage 320V, maximum voltage 480V).
Tig uP 353H AC/DC
Fuse 25A
CONNECTION
- Before making the electrical connections between
the current generator and the line switch, ensure
that the switch is turned off .
- The distribution panel must comply with the
regulations in force in the country of use.
- The mains system must be of the industrial type.
EATHINING
- To ensure user protection the welding machine
must absolutely be correctly connected to the earth
system (INTERNATIONAL SAFETY
REGULATIONS).
- It is indispensable to provide good earthing by
means of the yellow-green lead in the power cable,
in order to avoid discharges due to accidental
contacts with earthed objects .
- The chassis (which is conductive) is electrically
connected with the earth lead; if the equipment is
not suitably connected to earth it may cause
electric shocks which are dangerous for the user.
WATER COOLER
CONNECTION
LIFTING POWER SUPPLY
WARNING
:
The generator weighs 60 kg / 132 lb .
Lifting by hand:
Lift the power supply by using two handles
.
Lifting with hoist and strap
Lift the power supply by using ONLY the Eyelift
(do not use the handles)
Keep power supply as horizontal as possible
INSTRUCTION FOR
INSECURE POSITIONING
Failure to properly secure the machine con cause
personal injury.
If machine is in an insecure position do not attempt
to switch on.
Do not put the power source on an unlevelled
surface greater then a 10°.
The inverter generators
TIG µP
353H AC/DC
inverter generators
are already
equipped with a
coupling for connection to the
A.W.C. group.
N.B.)
To start the A.W.C. group it
is necessary to switch on both
the inverter generator and the
A.W.C. group.
Summary of Contents for 60532000L
Page 15: ...15 EXPLODED VIEW ...
Page 17: ...17 WIRING DIAGRAM CONNECTION ...
Page 19: ...19 WELDING TABLE STEEL ...
Page 20: ...20 WELDING TABLE ALLUMINIUM ...
Page 21: ...21 APPUNTI NOTES ...
Page 22: ...22 Info www stelgroup com tel 39 0444 639525 ...