7
ROCK.AIR.FIRE
A Glass front
To open, lift up and pull away
towards your body.
D Infra-red receiver for remote control
Hold the remote control close to the sensor
to turn the flame on/off.
C Gas canisters
Turn open before operation and turn closed
afterwards.
Available items • sm-ro-air-fire-bs ...
• sm-ro-air-fire-bt ...
• sm-ro-air-fire-gs ...
• sm-ro-air-fire-gt ...
B Lava rock/gas ignition
Do not place lava rocks in front of the gas ignition.
• POWER ON Press buttons 1 and 10 successi-
vely within 2 seconds. The ignition sequence
is initiated. First, the pilot burner starts to
ignite (ticking sound). As soon as the pilot
flame burns stably, the main burner also ig-
nites (also audible). The gas fire burns at the
factory-preset level.
• POWER OFF Press button 1 for at least 3
seconds. The gas supply is interrupted imme-
diately. The remaining gas that is still inside
the gas fire burns completely. The gas fire
extinguishes.
• FLAMES HEIGHER
• Press button 5 once, several times or conti-
nuously until the desired flame height is rea-
ched. If the button is pressed for longer than
30 seconds, or if the maximum flame height
is reached, an acoustic signal is emitted.
Model
Item
Gas
Pressure Connection Gas consumption
ROCK.AIR Fire Gas Tall
sm-ro-air-fire-gt Natural gas
20
n.s.
ROCK.AIR Fire Gas Tall
sm-ro-air-fire-gt Liquid gas
50
3-5 kg/h
ROCK.AIR Fire Gas Small
sm-ro-air-fire-gs Natural gas
20
1,42 m³/h
ROCK.AIR Fire Gas Small
sm-ro-air-fire-gs Liquid gas
50
1,17 kg/h
• FLAMES LOWER
Press button 9 once, several times or conti-
nuously until the desired flame height is rea-
ched. If the button is pressed for longer than
30 seconds, or if the minimum flame height is
reached, an acoustic signal is emitted.
• MODULATING FLAMES AUTOMATICALLY
Press button B (3) once. This is confirmed by a
single acknowledgement tone. The flames are
periodically enlarged and reduced.
• DEBUGGING / RESET
In the event of a fault, the gas fire switches off
for safety reasons. Before it can be restarted,
the control unit must be reset. Press button C.
If the fault occurs again, consult a specialist.
Power off 1
Power on:
Press 1 and 10 successively
within 2 sec
Debugging 4
Flame higher 5
Flame smaller 9
Fire noise generator (opt.) higher 8
Round button 10
Fire noise generator optional 2
Fire noise generator (opt.) lower 6
Automatic flame
modulation / Eco-
wave 3