Operation
Technical Specifications
In order to switch on the
light without a heat source
in the detection zone,
switch the indoor power
switch momentarily. This
will activate the light for
the period selected.
Weather can affect the
function of the sensor light
fixture. Strong gusts of
wind, snow, rain or hail may
cause switching errors,
because the unit cannot
distinguish the sudden
change of temperature.
The Fresnel lens should be
periodically wiped clean
with a damp cloth if it gets
dirty.
Do not use any cleaning
materials.
Line voltage:
220 – 240 V/50 – 60 Hz
Power output:
max. 60 watts (no low-energy bulbs)
Power consumption:
1.3 W
Detection angle of sensor:
360° all-round lens
(with 120° angle of aperture)
Swivelling range of sensor:
2 x 40° in every direction
ON time, adjustable:
10 sec. to 15 min.
Lighting threshold, adjustable:
2 – 2,000 lux
Sensor range (dependent on sensor setting,
ambient temperature, and direction of approach)
From the front:
12 m (40 ’)
From the side:
1
6 m (20 ’)
Type of enclosure:
IP 44, splashproof
Ambient temperature:
– 25 °C to + 55 °C (– 13 °F to + 131 °F)