Troubleshooting

Sensor
without power

Fuse has blown, not 
switched on

Short circuit

Replace fuse, switch on 
mains switch, check 
wiring with voltage tester

Check connections

Sensor
does not switch ON

Light threshold in 
nighttime mode during 
daytime operation

Bulb burnt out

Mains switch OFF

Fuse blown

Detection zone not 
properly targeted

Adjust setting

Replace light bulb

Switch power on

Replace fuse, check 
connection if necessary

Recalibrate

Sensor
does not switch OFF

Continued movement 
within the detection zone

Switched on light is with-
in detection zone and 
switches on again as a 
result of temperature 
change

Set to continuous 
operation by indoor
series switch

Check zone and readjust 
if necessary or apply 
shroud

Readjust zone or apply 
shrouds

Series switch to 
automatic

Sensor
keeps switching ON/OFF 

Switched on light is 
within detection zone

Animals moving in 
detection zone

Adjust detection zone or 
apply shrouds, increase 
distance

Adjust zone or apply 
shrouds

Sensor
switches on when 
it should not 

Wind is moving trees and 
bushes in the detection 
zone

Cars in street are 
detected

Sudden temperature 
changes due to weather 
(wind, rain, snow) or 
exhaust air from fans or 
open windows

Blank out areas with 
shrouds

Blank out areas with 
shrouds

Adjust detection zone or 
install in a different place

Malfunction

Cause

Remedy

Wiring examples

1. Fixture without neutral conductor

2. Fixture with neutral conductor

3. Connection via series switch for
manual and automatic operation

4. Connection to double-throw switch
for permanent light and automatic 
operation

Setting I: automatic operation
Setting II: manual operation for permanent
light
Note: the unit cannot be switched off, 
only optional operation between settings I
and II.

1)

e.g. 1-4 x 100 W filament bulbs

2)

Consumer, lighting max. 1000 W (refer to Technical specifications)

3)

Sensor connection terminals

4)

Indoor standard switch

5)

Indoor series switch, manual, automatic

6)

Indoor double-throw switch, automatic, permanent light

Operation/Maintenance

The motion sensor is suit-
able for automatic switching
of lights. The unit is not 
suitable for special burglary
alarm systems, since it
lacks the sabotage protec-
tion prescribed for this 
purpose. Weather can affect

operation of the sensor.
Strong gusts of wind, snow,
rain and hail can cause
switching errors, since the
sudden temperature fluctua-
tions cannot be distiguished
from heat sources. 
The detection lens can be

cleaned with a damp cloth
(without detergents) if dirty.

18

19

Serie_180_10spr.qxd  18.10.2004  15:50 Uhr  Seite 19

Summary of Contents for Serie IS 180

Page 1: ...g Operating instructions Mode d emploi Gebruiksaanwijzing Istruzioni per l uso Instrucciones de montaje Bruksanvisning Brugsanvisning Käyttöohje Bruksanvisning 7216602 Technische Änderungen vorbehalten Service Serie_180_10spr qxd 18 10 2004 15 50 Uhr Seite 1 ...

Page 2: ...f 180 with an opening angle of 90 is achieved The lens is removable and can be rotated This allows two basic reach settings of max 5 m or 12 m The infrared sensor can be installed without difficulty on inside and outside cor ners using the enclosed wall mounts Dimensions H x W x D 120 x 76 x 56 mm Output max 1000 W ohmic load e g filament bulb max 1500 W uncorrected inductive cos ϕ 0 5 e g fluores...

Page 3: ...of 5 12 m the installation height should be approx 2 m Installation steps 1 Remove decorative cover 2 Release catch and fold up lower half of housing 3 Mark drilling holes 4 Drill the holes and insert plugs 6 mm dia 5 Prepare wall according to needs for flush or sur face mounted wiring 6 Wire up the supply and service leads and connect Use sealing plugs for sur face mounted wiring a Connection of ...

Page 4: ...s paths or neighbouring property or to monitor these specifical ly the detection zone can be adjusted precisely by means of shrouds The sensor lens is divided into two detection zones With one half a max reach of 5 m is achieved and with the other a max reach of 12 m for an installation height of approx 2 m After fitting the lens press lens firmly into the channel provided you will see the max rea...

Page 5: ...air from fans or open windows Blank out areas with shrouds Blank out areas with shrouds Adjust detection zone or install in a different place Malfunction Cause Remedy Wiring examples 1 Fixture without neutral conductor 2 Fixture with neutral conductor 3 Connection via series switch for manual and automatic operation 4 Connection to double throw switch for permanent light and automatic operation Se...

Page 6: ...max réglage de précision par caches de 1 à 12 m Temporisation 10 s 15 min Réglage de crépuscularité 2 2000 lux Classe IP 54 Declaration of conformity Functional Warranty This product complies with the European Directive on Low Voltage Appliances 73 23 EEC and the EMC Directive 89 336 EEC This STEINEL product has been manufactured with great care and its operation and safety have been tested in con...

Reviews: