Twilight setting (response threshold)

The desired response threshold of the
light can be infinitely adjusted from
approx. 2 – 2000 lux. Turn control 

 

fully anticlockwise to select night-
time operation at about 2 lux. Turn
control 

 

fully clockwise to select

teach mode, shortly before this pos-

ition means daylight operation at about 2000 lux. 
(The light leaves the factory set to daylight operation.)

Teach mode:
At the light level at which you want the SensorLight 
to respond to movement, the control should be set 
to      . After 10 sec. the value of the ambient bright-
ness is saved. Before this time elapses, the glass
shade must be applied. There must be no LED 
module switched on.

Time setting (switch-off delay)

The chosen light ON time can be 
varied continuously from approx. 
1 sec. to a maximum of 20 min. 
(The light leaves the factory set to 
the shortest time.) Any movement
detected before this time elapses 
will re-start the timer.

Note: After the light switches OFF, it takes approx. 
1 sec. before it is able to start detecting movement
again. The light will only switch on in response to
movement once this period has elapsed.

Install mode:
If the setting below 1 is selected, the device will
switch to "install mode". The light switches on for 
3 sec. as soon as motion is detected. Unnecessary
waiting time can therefore be avoided during adjust-
ment. Since the lamp is subject to heavy wear in this
mode, the fixture quits the mode automatically after
10 min. The minimum time (1 min.) applies in this case.
This glass shade should also be applied in this mode.
Important: Teach mode and Install mode cannot be
used at the same time. The wireless module must not
be plugged in when using the Install mode.

Reach setting (sensitivity)

Reach is the term used to describe the
diameter of the more or less circular
detection zone produced on the ground
after mounting the sensor light at a
height of 2.5 m. Turn the reach control

fully anticlockwise to select minimum

reach (approx. 1 m dia.), and fully

clockwise to select maximum reach (approx. 8 m dia.).
(The light leaves the factory set to maximum reach.)

By inserting the shrouds supplied, the reaches can 
be reduced in four directions (see drawing 

).

Note: During adjustment, use the "install mode" 
(see time setting).

If a mains switch is installed in the mains supply lead,
the light is capable of the following functions in addition
to the simple ON/OFF function:

Sensor operation 
1) Switch light ON (when light is OFF): 
Turn switch OFF and ON once.
Light stays ON for the period selected.
2) Switch light OFF (when light is ON): 
Turn switch OFF and ON once.
The light goes out or switches over to sensor mode.

Manual override
1) Activate manual override: 
Turn switch OFF and ON twice. The light is set to 
manual override for 4 hours. 
2) Deactivate manual override:
Switch OFF and ON once. The light goes out or 
switches over to sensor mode.

Important:
The switch should be actuated in rapid succession 
(in the 0.5 – 1 sec. range).

Manual override

- 13 -

1

20

+

-

1  – 20 min.

*

only applies to RS PRO 500/1000 sensor

150

Lux

100

300

2 – 2000 lux

Installation

Installation 

*

Connecting the mains power supply lead (see Fig.).
The mains lead consists of a 3 phase cable.
L

= phase conductor (usually black or brown)

= neutral conductor (usually blue)
PE = protective earth conductor (green/yellow)

If you are in any doubt, identify the conductors using 
a voltage tester; then switch off the power again. The
cables must also be fitted with the heat-resistant wire
insulator. Connect the phase conductor (L) and neutral
conductor (N) to the terminal block. The protective
earth conductor may be sealed off with insulation tape.

Important: Reversing the connections will result in a
short-circuit in the light unit or in your fuse box later
on. In this case, you must identify the individual con-
ductors once again and re-connect them. A mains
switch for switching the unit ON and OFF may of
course be installed in the mains power supply lead.

Technical specifications

RS PRO 500 Sensor/Slave

RS PRO 1000 Sensor/Slave RS PRO 2000 Sensor/Slave

Wattage:

2 x 13 W (GU 24-Q1)

2 x 18 W (GU 24-Q2)

2 x 26 W (GU 24-Q3)

additionally max. 800 W

additionally max. 800 W

additionally max. 800 W

Connection:

230-240 V/50 Hz

Installation site:

indoors, wall/ceiling mounting

HF-system 

*

:

5.8 GHz CW radar, ISM band

Transmitter output 

*

:

approx. 1 mW

Detection 

*

:

360°, 160° angle of aperture, if necessary through glass, wood and stud walls

Reach 

*

:

1 – 8 m dia., infinitely variable

Time setting 

*

:

1  – 20 min.

Twilight setting 

*

:

2 – 2000 lux, does not recognise artificial light with conventional ballast

Manual override 

*

:

selectable (4 hours)
provided switch is connected in mains supply lead

Enclosure:

IP 44

Power consumption 

*

:

approx. 0.9 W

- 12 -

Important: Make sure the installation site is not 
subject to vibration. Always fit the sealing plugs to
prevent insects (spiders etc.) getting inside and 
activating the light.

Connecting a dimmer will result in damage to the
SensorLight.

Connection of an additional load
An additional load with max. 800 W can be connected
to the SensorLight, switched by the electronics. The
models RS Pro 500 SLAVE and RS Pro 1000 SLAVE
have been developed for this purpose, which create 
a uniform appearance and offer additional functions
at the same time. Screw the live conductor to the live
fixture to the terminal marked L’ on the SensorLight.
First remove the protective cap with a pair of pliers.
The cables must also be fitted with the heat-resistant
wire insulator. Clamp the neutral conductor in the ter-
minal marked together with the neutral conductor
of the mains power supply lead. If the connected light
fixture requires a protective earth conductor, this is to
be connected with a "flying terminal".
Please observe the connection diagrams with regard
to use of the accessory modules.

*

only applies to RS PRO 500/1000 sensor

Safety warnings

Disconnect the power supply before attempting
any work on the unit. 

During installation, the electrical wiring you are
connecting must be dead. Therefore, switch off the
power first and use a voltage tester to make sure
the wiring is off circuit. 

Installing the SensorLight involves work on the
mains voltage supply. This work must therefore 
be carried out professionally in accordance with
applicable national wiring regulations and electrical
operating conditions.  (

D

- VDE 0100, 

A

-ÖVE /

ÖNORM E8001-1, 

-SEV 1000)

Only use genuine replacement parts.

Repairs may only be carried out by specialist
workshops.

Disconnect the power supply before changing 
the lamp.

GB

+

-

1 m–8 m dia.

After the wall mount/ceiling holder 

has been

installed and the mains connection has been made,
the SensorLight can be used for the first time. When
the light is turned on manually at the light switch, it
switches off after 10 secs. for the calibration phase
and is then activated for operation in the sensor
mode. It is not necessary to operate the light switch 
a second time.

Functions 

*

Recommendation:
Fluorescent tube manufacturers recommend season-
ing, or burning in, new tubes for 100 hours so as not
to restrict tube service life. To follow this recommen-
dation and to ensure trouble-free sensor operation
particularly at low ambient temperatures, new fluores-
cent tubes should undergo the following seasoning
procedure. 
1. Connect light and switch "ON". 
2. Turn all 3 setting controls fully clockwise, then turn

the middle setting control fully anticlockwise and
fully clockwise again (within 10 sec.). 

3. The seasoning process is confirmed by switching

the light „OFF“ twice and then back "ON" again.

4. Now turn all controls to the chosen settings. 
5. The light is now left "ON" for 100 hours without

sensor function. Do not disconnect the light from
the mains power supply during this period. 

6. The luminaire automatically returns to sensor

mode after 100 hours.

Note: 
When fluorescent tubes are new or at low ambient
temperatures, the sensor may not switch the light
"OFF" as it might be detecting gas moving inside 
the tubes. In this case, switch the light "OFF" and, 
for the time being, drastically reduce the reach set-
ting. Please only use high-quality branded lamps.
Otherwise, we cannot guarantee that the high-
precision sensor will operate reliably.

PK Elektronik Vertriebs GmbH, E-Mail: [email protected], Internet: www.pkelektronik.com

Summary of Contents for RS PRO Series

Page 1: ...i RS PRO 500 RS PRO 1000 RS PRO 2000 110011166 08 2011_B Technische nderungen vorbehalten PK Elektronik Vertriebs GmbH E Mail info pkelektronik com Internet www pkelektronik com...

Page 2: ...13 W RS Pro 500 Sensor RS Pro 500 Slave Sensor Slave Sensor Sensor Sensor Slave Sensor Sensor Sensor Sensor Slave Slave Sensor M UG EG 1 OG UG EG 1 OG EG EG 2 OG 3 OG 1 OG Sensor Sensor Slave Slave Se...

Page 3: ...or RS PRO 1000 2000 Slave Lux 100 300 150 1 20 Sensor RS Pro 1000 RS Pro 2000 2x 18 W 2x 26 W 5 RS PRO 500 Sensor RS PRO 500 Slave 4 PK Elektronik Vertriebs GmbH E Mail info pkelektronik com Internet...

Page 4: ...t Sicherungskasten Licht bei Strom Sicherungsausfall mit optionalem LED Orientierungslichtmodul Akku Beide Leuchten werden durch die Bewegungs erfassung der Master Einheit mit integriertem Sensor akti...

Page 5: ...haltet da er unter Umst nden die Bewegung des Gases in den Leuchtmitteln er kennt In diesem Fall die Leuchte ausschalten und die Reichweiteneinstellung zun chst stark reduzieren Bitte verwenden Sie nu...

Page 6: ...tet Leitung unterbrochen Kurzschluss in der Netzzuleitung Eventuell vorhandener Netzschalter aus neue Haussicherung Netzschalter einschalten Leitung berpr fen mit Spannungspr fer Anschl sse berpr fen...

Page 7: ...Sensor Slave Wattage 2 x 13 W GU 24 Q1 2 x 18 W GU 24 Q2 2 x 26 W GU 24 Q3 additionally max 800 W additionally max 800 W additionally max 800 W Connection 230 240 V 50 Hz Installation site indoors wal...

Reviews: