11. Troubleshooting
Malfunction
Cause
Remedy
LED floodlight without power
■
Fuse has blown,
not switched ON, break in wiring
■
Short circuit
■
New fuse, turn on power switch,
check wiring with voltage tester
■
Check connections
Sensor-switched LED
floodlight will not switch ON
■
Twilight setting in night-time mode
during daytime operation
■
Mains switch OFF
■
Fuse blown
■
Detection zone not correctly
adjusted
■
Reset
■
Switch ON
■
Replace fuse, check connection
if necessary
■
Readjust
Sensor-switched LED
floodlight will not switch OFF
■
Continued movement within the
detection zone
■
Check zone and readjust if
necessary or apply shroud
Sensor-switched LED
floodlight keeps switching
ON and OFF
■
Animals moving in detection zone
■
Tilt sensor higher or fit shrouds to
target sensor; adjust detection
zone or fit shrouds
Sensor-switched LED
floodlight switches ON when
it should not
■
Wind is moving trees and bushes in
the detection zone
■
Cars in the street are detected
■
Sudden temperature changes due
to weather (wind, rain, snow) or air
expelled from fans, open windows
■
Sensor-switched LED floodlight
swaying (moving), resulting, for
example, from gusts of wind or
heavy precipitation
■
Change detection zone
■
Change detection zone
■
Adjust detection zone or install
in a different place
■
Fit sensor-switched LED floodlight
to a firm surface
GB
Summary of Contents for professional XLED PRO 240
Page 6: ...6 5 8 5 9 5 10 5 11 6 mm 5 12 5 13 5 14 5 15...
Page 7: ...7 5 16 Master L N L L N N L L 5 17 Slave L N 5 18 5 19 5 20 I O 6 6 1...
Page 67: ...67 8 15 15 8 LED 1 LED 6 3 6 4 6 5 6 6 7 LED LED 8 9 5 STEINEL Professional Sensorik GR...
Page 127: ...127 6 XLED PRO 240 S 8 F 2000 6 1 6 2 E 2 2000 2 6 2 F 8 15 15 8 1 6 3 6 4 6 5 6 6 7 RU...
Page 130: ...130 XLED PRO 240 S XLED PRO 240 S XLED PRO 240 240 10 15 2 2 000 IP IP44 II 11...
Page 134: ...134 68 1756 STEINEL www tashev galving com 359 2 700 45 454 5 5HERSTELLER GARANTIE...
Page 141: ...141 11 LED LED LED LED LED LED LED...