Electrical installation/automatic mode
Wiring example/manual switch-off
Wiring example semi-automated BLS T
BLS / BLS T
BLS
BLS D / BLS DF
BLS D / BLS DF
L
L
N
L
L
N
+
In selecting the wiring leads, the
wiring regulations according to
VDE 0100 must be complied
with (see safety warnings on
page 12). The following applies
for wiring of the BLS D and
BLS DF: According to VDE 0100
520 sect. 6, a multiple lead may
be used for wiring between the
sensor and electronic ballast,
containing both the mains volt-
age leads and the control leads
(1–10 V) (e.g. NYM 5 x 1.5
2
).
The mains supply lead must
be no greater than 10 mm in
diameter.
The clamping range of the
mains terminal is designed for
a maximum of 2 x 1.5 mm
2
or
1 x 2.5 mm
2
.
15
If it is to be possible to delib-
erately switch off the auto-
matic function of the sensor
manually, a conventional
switch is to be positioned
upstream from the sensor.
1) Light group, 2) BLS, 3) External switch
1) Break-contact button, 2) BLS T, 3) Load, lighting
4) Light with dimming electronic ballast, 5) BLS D / BLS DF
Assembly/Installation
Installation procedure
1. Pull off the decorative
ring by pressing lightly on
the sides and simultaneous-
ly turning downwards.
2. Unscrew the
locking
screw.
3. Pull the sensor enclosure
off the mounting plate
in the direction of the
arrow
.
4. Install the mounting plate
under the ceiling using the
enclosed screws and dow-
els.
5. Perform wiring (see Electri-
cal installation).
– Neutral conductor N
– Phase L
– Switched phase L
– Earth conductor (protective-
earth conductor)
– Control
– Control output –
– (only BLS D and BLS DF)
For surface wiring, the groove
on the decorative ring is to be
pierced and the cable is to be
introduced from the side.
16. Push-fit the sensor hous-
ing on to the mounting
plate from the side
(against the direction of
the arrow)
.
17. Screw in the locking
screw
.
18. Perform a function test
and adjust the detection
zone (see pages 16 and 19).
19. Adjust the switch-off delay
and brightness setting on
the front of the enclosure
(control dial) (see Func-
tions p. 17, Adjustments
section).
10. Apply the decorative ring
(clip in place). (Shrouds
are fixed with the decora-
tive ring).
14
Mains lead
Light with
dimming
electonic ballast
(e.g. NYM 5 x 1.5
2
)
Mains lead
e.g. NYM 3 x 1.5
2
Light
LuxMaster_10spr 27.08.2008 13:32 Uhr Seite 16
PK Elektronik Vertriebs GmbH, E-Mail: [email protected], Internet: www.pkelektronik.com