3 6

Reach setting/adjustment

Reach setting / examples

- 12 -

The system can be put into
operation after connecting 
the motion detector. 

Two activation options are
provided after detaching the
decorative ring 

2

.

Twilight setting

The motion detector's
response threshold can be
infinitely varied from approx. 
2 to 2000 lux. Turning adjust-
ment screw fully anticlockwise

1

selects daylight operation

at adjustment screw 2000 lux.
Turning setscrew fully clock-
wise 

6

selects night-time

operation at approx. 2 lux.

(The IS 360 D TRIO is factory-
set to daylight operation.) 
The adjustment screw must
be turned fully anticlockwise
for defining the sensor's
detection zone and performing
the function test in daylight.

Switch-off delay
(time setting)

The chosen duration of illumi-
nation of the connected lamp
is infinitely adjustable between
approx. 10 sec. to a maximum
of 15 min. Turning the adjust-
ment screw fully anti-clock-
wise 

1

selects the shortest

time of approx. 10 sec., 

turning the adjustment screw
fully clockwise 

6

the longest

time of approx. 15 min. 
(The IS 360 D TRIO is factory-
set to the shortest time.) 
The shortest time setting is
recommended for defining the
sensor's detection zone and
performing the walk test.

At an assumed mounting
height of 2.5 m, the maximum
reach of the sensor is 12 m.
The detection zone setting
can be optimised to suit
requirements. The shrouds 

6

provided are used for masking
out off any number of lens
segments or to shorten reach
as required.

This prevents the light from
being activated unintentional-
ly, e.g. by cars, passers-by
etc. and allows you to target
danger spots. The shrouds 

6

can be divided or cut with a
pair of scissors along the ver-
tical and horizontal grooves 

6

After detaching the decorative
ring 

2

, clip these in at the top

of the sensor lens. Now push
the decorative ring 

2

back on

again to hold the shrouds 

6

firmly in place. You can turn
the sensor housing through 
± 10°

3

for precision adjust-

ment.

Functions

Reach setting/adjustment

approx. 10 sec.- 

max. of 15 min.

GB

Summary of Contents for IS 360 D TRIO

Page 1: ...4 Oslo Tel 47 22725000 Fax 47 22725001 post vilan no GR PANOS Lingonis Sons O E Aristofanous 8 Str GR 10554 Athens Tel 30 210 3212021 Fax 30 210 3218630 lygonis otenet gr PL LŁ Spółka z ograniczoną odpowiedzialnością sp k Byków ul Wrocławska 43 PL 55 095 Mirków Tel 48 71 3980861 Fax 48 71 3980819 firma langelukaszuk pl CZ ELNAS s r o Oblekovice 394 CZ 67181 Znojmo Tel 420 515 220126 Fax 420 515 24...

Page 2: ... seblende 5 vorgesehen Diese können leicht durch stoßen werden Wenn die Kabel durchgeführt sind kann die Montageplatte angeschraubt werden Zuletzt die Gehäuseblende 5 wieder aufziehen und einrasten n Anschluss der Netzzuleitung Die Netzzuleitung besteht aus einem 2 bis 3poligen Kabel L stromführender Leiter meistens schwarz braun oder grau N Nullleiter meistens blau PE eventueller Schutz leiter gr...

Page 3: ...o this lightly pinch both depressions while twisting it anti clock wise and pull it down and off Using a screwdriver now undo both fixing screws 1 anti clockwise and remove the mounting plate Do not detach internal wiring from terminal block but gently pull out entire terminal assembly Fit the rubber plug provided into the mounting plate Hold the mounting plate against the ceiling and mark where t...

Page 4: ...y anti clock wise 1 selects the shortest time of approx 10 sec turning the adjustment screw fully clockwise 6 the longest time of approx 15 min The IS 360 D TRIO is factory set to the shortest time The shortest time setting is recommended for defining the sensor s detection zone and performing the walk test At an assumed mounting height of 2 5 m the maximum reach of the sensor is 12 m The detectio...

Page 5: ...ow or air expelled from fans open windows n Change zone or fit shrouds n Change zone or fit shrouds n Change detection zone change site of installation 14 14 1 Light without neutral conductor 2 Light with neutral conductor 3 Connection using series switch for manual and automatic operation 1 e g 1 4 x 100 W filament bulbs 2 Loads lighting of 1000 W max see Technical specifications 3 IS 360 D TRIO ...

Page 6: ... do svorky označené L Nulový vodič modrý kabel se pro střednictvím svorky ozna čené N propojí s nulovým vodičem síťového přívodní ho vedení Stávající zele nožlutý ochranný vodič se připevní ke spodní svorce Důležité Záměna vodičů později způsobí zkrat v pří stroji nebo ve vaší pojistko vé skříni V tomto případě je nutno jednotlivé kabely opakovaně identifikovat a poté znovu zapojit V přívodním síť...

Reviews: