11. Troubleshooting

Malfunction

Cause

Remedy

Sensor not detecting 

motion

 

Sensor is not wired 

properly to the Data Line 

of the Controller

 

In the DCS App check 

if the bus connection is 

working properly over 

the LED blinking func-

tion available on the 

sensor settings page

Sensor is wired up 

properly but still not 

reacting to motion

 

Additional sensor set-

tings in the DCS App 

need to be checked and 

corrected

 

Check complete assign-

ment of the sensor func-

tionalites for the itended 

lighting zones in the App 

configuration. Make sure 

the sensor is assigned 

to the proper zone and 

the desired sequence of 

operation is selected

Sensor sending 

motion detection 

signal when it should 

not

 

There is interference, 

e.g. fan, air conditioning 

system or other source 

of heat, in the detec-

tion zone

 

Sensor near Wi-Fi or 

other wireless communi-

cation source

 

Relocate the sensor

 

 

 

 

Install at least 6 ft away 

from the wireless com-

munication source

Summary of Contents for Control Pro DT Quattro DCS

Page 1: ...LV LT EST HR SLO RO PL SK CZ H TR GR N FIN DK S P E I NL F GB D Information IR Quattro MICRO DCS IR Quattro Slim XS DCS IR Quattro DCS IR Quattro HD DCS US Quattro DCS US Oneway DCS DT Quattro DCS US...

Page 2: ...IR Quattro MICRO DCS 3 IR Quattro SLIM XS DCS 15 IR Quattro DCS 31 IR Quattro HD DCS 31 US Quattro DCS 49 US Oneway DCS 49 DT Quattro DCS 49 US Hallway DCS 49...

Page 3: ...US RU CN BG LV LT EE HR SI RO PL SK CZ HU TR GR NO FI DK SE PT ES IT NL FR GB DE Information IR Quattro MICRO DCS...

Page 4: ...4...

Page 5: ...5 3 1 3 2 2 79 in 71 mm 1 69 in 43 mm...

Page 6: ...6 3 3 A B 4 1 Polarity insensitive Dataline Dataline or or...

Page 7: ...7 5 1 19 6 ft 6 m 9 1 ft 2 8 m...

Page 8: ...8 5 2 19 6 ft 6 m 13 1 ft 4 m 5 3 1 38 in 35 mm 4 72 in 120 mm...

Page 9: ...9 5 4...

Page 10: ...rared presence puts on a great performance covering 36 m IP65 protection from the front makes it suitable for rooms exposed to moisture and sofit The two wire polarity insensitive Data Line Input comm...

Page 11: ...ode In case of a Data Line bus reset the sensor LED will blik indicating sensor adressing 7 Maintenance care The product requires no maintenance The detector lens may be cleaned with a damp cloth if i...

Page 12: ...R Square detection zone Coverage at 2 8 m 9 ft installation height radially 13 1 x 13 1 ft 4 x 4 m tangentially 19 6 x 19 6 ft 6 x 6 m Angle of coverage 360 Light measurement 0 2 92 fc Mounting height...

Page 13: ...pp need to be checked and corrected Check complete as signment of the sen sor functionalites for the itended lighting zones in the App con figuration Make sure the sensor is assigned to the proper zon...

Page 14: ...000000000 07 2013 Technische nderungen vorbehalten...

Page 15: ...15 RUS CN BG LV LT EST HR SLO RO PL SK CZ H TR GR N FIN DK S P E I NL F GB D IR Quattro SLIM XS DCS Information US...

Page 16: ...16 3...

Page 17: ...17 3 1 3 2 3 14 in 80 m m 1 77 in 45 m m 3 14 in 80 mm 2 00 in 51 m m...

Page 18: ...18 3 3 C A B D DA DA 4 1 DA DA Polarity insensitive Dataline Dataline or or...

Page 19: ...19 5 1 19 6 ft 6 m 9 1 ft 2 8 m...

Page 20: ...20 5 2 19 6 ft 6 m tangential 13 1 ft 4 m radial presence 5 3 2 67 in 68 mm 2 24 in 57 mm...

Page 21: ...21 5 4 5 5 DA DA DA DA...

Page 22: ...22 5 6...

Page 23: ...23 6 1 75 60...

Page 24: ...24 6 2 100 75 60 6 3...

Page 25: ...tina lens and square detection zone 13 1 x 13 1 ft 4 x 4 m presence detection zone 19 6 x 19 6 ft 6 x 6 m tangential detection zone The two wire polarity insensitive Data Line Input communicate motion...

Page 26: ...etection zone Detection zone Fig 6 1 6 2 The film shroud provided is used for minimising the detection zone by a maximum of 40 7 Function Setting The motion detection values and light levels measured...

Page 27: ...ered or subjected to abuse accident improper installation or impropesr use There are no obligations or liabilities on the part of STEINEL for consequential damages arising out of or in connection with...

Page 28: ...red PIR Square detection zone Coverage at 2 8 m 9 ft installation height radial presence 13 1 x 13 1 ft 4 x 4 m tangential 19 6 x 19 6 ft 6 x 6 m Angle of coverage 360 Light measurement 1 92 fc 10 100...

Page 29: ...the DCS App need to be checked and corrected Check complete as signment of the sen sor functionalites for the itended lighting zones in the App con figuration Make sure the sensor is assigned to the p...

Page 30: ...30 000000000 07 2013 Technische nderungen vorbehalten...

Page 31: ...31 RUS CN BG LV LT EST HR SLO RO PL SK CZ H TR GR N FIN DK S P E I NL F GB D IR Quattro HD DCS IR Quattro DCS US Information IR Quattro DCS IR Quattro HD DCS...

Page 32: ...32 3...

Page 33: ...33 3 1 IR Quattro DCS 4 72 in 120 mm 3 03 in 77 mm 4 72 in 120 mm 3 2 IR Quattro HD DCS 2 83 in 72 mm 4 72 in 120 mm 4 72 in 120 mm...

Page 34: ...34 3 3 IR Quattro DCS 13 1 ft 4 m 16 4 ft 5 m 22 9 ft 7 m 3 4 IR Quattro HD DCS 26 2 ft 8 m 26 2 ft 8 m 65 6 ft 20 m...

Page 35: ...5 m 1 5 ft 1 2 3 1 2 3 Coverage diagram at 9ft mounting hight Coverage diagram at 9ft mounting hight 3 6 IR Quattro HD DCS 5 5 4 4 3 3 2 2 1 1 0 16 m ft 16 13 13 9 5 9 5 6 5 6 5 3 3 0 14 12 10 8 0 6 2...

Page 36: ...36 4 1 Polarity insensitive Dataline Dataline or or 5 1 min 2 67 in 68 mm max 3 00 in 76 mm 4 72 in 120 mm...

Page 37: ...37 5 2...

Page 38: ...38 5 3 Load module Sensor module...

Page 39: ...39 5 4 Load module 5 5 Sensor module 6 1...

Page 40: ...t 5 1 m x 5 1 m 16 5 ft x 16 5 ft 5 5 m x 5 5 m 18 ft x 18 ft 4 3 9 m x 3 9 m 12 5 ft x 12 5 ft 3 9 m x 3 9 m 12 5 ft x 12 5 ft 4 5 m x 4 5 m 14 5 ft x 14 5 ft 5 5 m x 5 5 m 18 ft x 18 ft 5 5 m x 5 5...

Page 41: ...ft 8 2 m x 8 2 m 26 5 ft x 26 5 ft 11 m x 11 m 36 ft x 36 ft 28 m x 28 m 91 5 ft x 91 5 ft 4 00 m 13 ft 1 3 5 m x 3 5 m 12 5 ft x 12 5 ft 3 5 m x 3 5 m 12 5 ft x 12 5 ft 6 m x 6 m 19 5 ft x 19 5 ft 7...

Page 42: ...25 ft 26 m x 26 m 85 ft x 85 ft 7 7 8 m x 7 8 m 25 5 ft x 25 5 ft 30 m x 30 m 98 ft x 98 ft 8 00 m 26 ft 1 7 4 m x 7 4 m 24 ft x 24 ft 11 m x 11 m 36 ft x 36 ft 2 7 5 m x 7 5 m 24 5 ft x 24 5 ft 15 m...

Page 43: ...o longer than 328 ft 100 m 20 AWG 492 ft 150 m 18 AWG 656 ft 200 m 16 AWG 984 ft 300 m 14 AWG After the sensor is powered on it flashes for 10 s US 1 Installer This high quality product has been manuf...

Page 44: ...tes Follow the next steps on the commissioning App of the DCS Mounting procedure 2 Connect to the bus powered data line of the room controller Fig 4 1 5 3 Mount the power module to a 4 Square box 4 Oc...

Page 45: ...if it gets dirty do not use cleaning agents 8 Disposal Electrical and electronic equipment accessories and packaging must be recycled in an environmentally compatible manner Do not dispose of electri...

Page 46: ...Coverage at 2 8 m 9 ft installation height IR Quattro DCS presence max of 15 x 15 ft 225 sq ft 4 7 x 4 7 m 22 sq m radially max of 15 x 15 ft 225 sq ft 4 7 x 4 7 m 22 sq m tangentially max of 23 x 23...

Page 47: ...the DCS App need to be checked and corrected Check complete assign ment of the sensor func tionalites for the itended lighting zones in the App configuration Make sure the sensor is assigned to the p...

Page 48: ...48 000000000 09 2013 Technical changes subject to no prior notification...

Page 49: ...S Quattro DCS US Oneway DCS DT Quattro DCS US Hallway DCS RUS CN BG LV LT EST HR SLO RO PL SK CZ H TR GR N FIN DK S P E I NL F GB D US Information US Quattro DCS US Oneway DCS DT Quattro DCS US Hallwa...

Page 50: ...50 3...

Page 51: ...51 3 1 US Quattro DCS DT Quattro DCS 2 83 in 68 mm 4 72 in 120 mm 4 72 in 120 mm 3 2 US Oneway DCS US Hallway DCS 2 87 in 73 mm 4 72 in 120 mm 4 72 in 120 mm...

Page 52: ...ION Coverage diagram at 9ft mounting hight One grid line 1m 3 3 ft m ft 19 7 19 7 16 16 13 13 9 5 9 5 6 5 6 5 3 3 3 3 0 3 4 US Oneway DCS US Hallway DCS Us hallway US oneway Coverage diagram at 9ft mo...

Page 53: ...53 4 1 Polarity insensitive Dataline Dataline or or 5 1 US Oneway DCS US Hallway DCS...

Page 54: ...54 5 2 min 2 67 in 68 mm max 3 00 in 76 mm 4 72 in 120 mm...

Page 55: ...55 5 3...

Page 56: ...56 5 4 Load module Sensor module...

Page 57: ...57 5 5 Load module 5 6 Sensor module...

Page 58: ...Data Line provided by the DCS in either way The sensor is intended for concealed indoor installation in ceilings and sofit Wire labelling Red and blue polarity insensitive US 1 Installer This high qu...

Page 59: ...Red LED During installation and Data Line addressing LED flashes 1 x per second The lead between the DCS and the sensor must be no longer than 984 ft 300 m for 1 5 mm 14 AWG After the sensor is power...

Page 60: ...d electronic equipment as domestic waste 9 Warranty STEINEL America warrants its products against defects in material or workmanship for a period of five years STEINEL will replace or repair the item...

Page 61: ...R Single pyro 11 detection levels 520 switching zones Ultrasonic 40 kHz US Oneway DCS US Hallway DCS US Quattro DCS Ultrasonic 40 kHz Square detection zone Coverage at 2 8 m 9 ft installation height U...

Page 62: ...radially max of 13 0 x 13 0 ft 4 0 x 4 0 m tangentially max of 26 x 26 ft 8 0 x 8 0 m Light measurement 1 92 fc 10 1000 lux Mounting height 2 5 3 5 m 8 12 ft IP rating IP 20 For indoor use only Tempe...

Page 63: ...the DCS App need to be checked and corrected Check complete assign ment of the sensor func tionalites for the itended lighting zones in the App configuration Make sure the sensor is assigned to the p...

Reviews: