background image

STEINDORFF

®

 

 

- 7 -

 

1.Press “M” shortly to get into the Capture mode. Press “OK” to take pictures. 
2.Press “Capture” on the monitor only. 
3.Press “Capture” button on the IR remote to get pictures.   

 

* To record videos: 
1.Press “M” shortly to get into the Record mode. Press “OK” to start recording. 
2.Press “OK” to stop recording. 
PS: Press “Lock & unlock” on the remote to lock the file when it’s recording. So the video file won’t be covered 
by new files when the memory card is full. 
 

HDMI 

·First, make sure that the monitor connecting to the microscope is literally HDMI monitor. Otherwise it won’t 
perform as good as we expected. 
·Second, connect the microscope to the HDMI monitor, also, connect it to the power supply. Because there is 
no built-in battery in the device, so make sure the microscope is always in charging when you use it.   
·Third, turn on the microscope and adjust the distance. Then put the object on the table and adjust the focus 
controller. 
·It won’t show anything on its own screen when it is connected to other equipment. So it’s normal that when you 
use it as HDMI output, the 5 inch screen keeps being dark.   
·You still can take pictures and save them if you have a memory card inside the microscope. But you can’t record 
videos in this output mode. 

 

FAQ 

•Why is there no image on the monitor? 
Please check all the cables connect properly and also make sure the device is switched on.   
•Why the image is not clear? 
Please adjust the object distance and the focus controller, check the direction of the LED lights, and make sure 
the lens is clean enough. 
•Remote doesn’t work? 
There is no battery inside of the remote as standard configuration. Please check if there is battery in the remote.   
•Why is there no image in playback model? 
Sometimes the video file is too big, the system needs time to process. 
•SD card error 
Make sure the memory card you use is certified and quality. Format the memory card in the system first, then try 
again.   
 

USB 

 

Software Installation 

Download the software first:   

 
So far the measuring software “Andonstar” can only support Windows system. If you can’t open the links or get 
problem with downloading these files, please ask customer service to send you separately. You can also go visit 

Summary of Contents for NYMCS-VM400

Page 1: ...STEINDORFF NYMCS VM400 Instructions...

Page 2: ...ameters 2 Parts List 3 Main Device 3 Remote Controller 4 Connect Outputs 5 General Use 6 Use Individually 6 HDMI 7 USB 7 Software Installation 7 Software Operation 8 Icons Definitions 8 Interface Defi...

Page 3: ...lectronic equipment does not belong to domestic waste but must be disposed in accordance with the applicable statutory provisions In order to bring customers a better experience we may change the prod...

Page 4: ...EINDORFF 3 Parts List Main Device Fasten screw It aim to adjust the compactness between the Lifting stand and the Distance controllers so users can fasten the distance from the lens to the object tabl...

Page 5: ...the file when it s recording So the video file which has been locked won t be covered by new files when the memory card is full Sharpness up down there are three levels of sharpness Soft Normal Strong...

Page 6: ...them AV output You need a separated AV cable to connect the device to the monitor when you need to use AV output There is no AV cable in the standard configuration Memory card In order to save video...

Page 7: ...e UP DOWN to zoom in out To switch mode 1 Press M shortly Or press the Mode on the remote 2 Icons definition in different modes standby mode capture mode record mode image playback mode video playback...

Page 8: ...ther equipment So it s normal that when you use it as HDMI output the 5 inch screen keeps being dark You still can take pictures and save them if you have a memory card inside the microscope But you c...

Page 9: ...stance of a line and a circle Radius length Distance of 2 horizontal points Add a square mark Distance of 2 vertical points Add a circle mark Distance of any 2 points Add text Measuring a rectangular...

Page 10: ...w all pictures they ve captured Users can also edit the picture by right clicking the picture and open it in the main operating window Choose View Toolbars and Docking Windows Picture browser to show...

Page 11: ...Shows the size of the Calibrations Users can apply whole view Users Can or delete the one they want change it in File Videosetting Video capture pin S Where to set new Shows all results of Calibrators...

Page 12: ...any more 2 In the Calibration management set the name and unit length of the new calibration refer the picture on the right Then click Calibration meanwhile the in the toolbar should have been chosen...

Page 13: ...ce the results of measuring in a proper place around the target 3 Special Effect Includes Edge detection Inverse color Flip horizontal Relief Sharpen and Smooth Steps 1 Choose the special effect you n...

Page 14: ...on or initiator procedure Please confirm that in the system there are Microsoft Net Framework 4 0 and Microsoft Visual C 2010 Runtimes 2 The software works fine but the software can not recognize the...

Page 15: ...ly high temperature environment etc 3 If the fault caused by accident oversight mis operation or natural disasters etc 4 If the fault caused by people who are not belong to authorized organizations of...

Reviews: