Procedure for disconnecting a work tool for example a bucket is the following.
1.
Crowd in the tiltrotator so that the work tool hangs in the work tools front bracket pin
2.
Activate the quick coupler safety switch and pressurize the system. The locking pins are retracted to the open
position. The buzzer should sound and indicate that the safety switch is now in an unsafe state. This is also
indicated by a red indicator bar (left) and on the display.
3.
Gently put the work tool on the ground. When the tool is placed on the ground, the bucket cylinder is retracted
so that the quick coupler rear grip is released from the bucket adapter.
4.
Lift the dipper arm so that the quick coupler is released from work tools front bracket pin.
5.
Turn the quick coupler safety switch off, pressurize the system and the locking wedge will be pushed out to the
locked position. This is indicated by a green indicator bar (right) becoming visible and the red indicator bar (left
no longer being visible.
5.10. Using the lifting hook
The lifting hook must always be used with great care. Always check lifting equipment before every lift and always
lift as low as possible.
Warning: Only use approved lifting chains/lifting straps and never lift a greater weight than stated on the
quick coupler machine plate.
Warning: Ensure that nothing that can be damaged is within a safety radius of three meters plus the
greater of the lifted object height or length.
Warning: Never lift outside the hook lifting area as illustrated below.
User Manual tiltrotator with Front pin lock
™
| 5. Operation |
37
Summary of Contents for Tiltrotator Front pin lock X04
Page 2: ......
Page 16: ......
Page 26: ......
Page 48: ......
Page 54: ......
Page 55: ...Chapter 8 8 Environmental aspects Topics Environmental information ...
Page 63: ......
Page 64: ...Steelwrist AB Bäckvägen 18 192 54 Sollentuna Sweden 46 626 07 00 www steelwrist com 700347ENA ...