background image

LINE
   1 

LINE
   1 

Assembly Directions
93-9501147  REV  -

Page

2 of 4

Panel Base Receptacle Installation

Remove trim by pushing down on steel tabs at the bottom extreme 
ends (in area of glides) and lifting straight up and out.

1.

APPLY PRESSURE TO STEEL TABS

BASE TRIM

Position duplex receptacle to panel powerway assembly.  
Secure receptacle with (2) screws

2.

STRUCTURAL PANEL

POWERWAY

SCREWS

DUPLEX

RECEPTACLE

Remove access cover from base trim.

3.

ACCESS 

COVER

BASE

TRIM

Replace trim by reversing removal procedure.

NOTE: If receptacle and base trim do not align, the 
powerway may be adjusted by loosening the (2) 
powerway mounting screws and sliding the power-
way to either end.  Re-tighten screws and replace 
base trim.

4.

DUPLEX

RECEPTACLE

BASE

TRIM

Summary of Contents for 98665-1

Page 1: ... 5 WIRE POWERWAY SYSTEM WIRING INFORMATION Steelcase Inc Grand Rapids MI 49501 U S A 1 800 227 2960 Tools Assembly Directions Printed In U S A REV 93 9501147 Page 1 of 4 Installation For 4 5 Wire Duplex Receptacle Into Series 9000 Structural Panel 2 P Series Mobiles Power Panel Series 9000 Energy Management Worksurface All electrical installations should be done by a qualified person in accordance...

Page 2: ...n duplex receptacle to panel powerway assembly Secure receptacle with 2 screws 2 STRUCTURAL PANEL POWERWAY SCREWS DUPLEX RECEPTACLE Remove access cover from base trim 3 ACCESS COVER BASE TRIM Replace trim by reversing removal procedure NOTE If receptacle and base trim do not align the powerway may be adjusted by loosening the 2 powerway mounting screws and sliding the power way to either end Re ti...

Page 3: ...receptacle to panel powerway assembly Secure receptacle with 2 screws 2 Remove access cover from base trim 3 Replace trim by reversing removal procedure NOTE If receptacle and base trim do not align the powerway may be adjusted by loosening the 2 powerway mounting screws and sliding the power way to either end Re tighten screws and replace base trim 4 BASE TRIM PANEL ASSEMBLY LINE 1 SCREWS DUPLEX ...

Page 4: ...eries 9000 Energy Management Worksurface Open worksurface channel cover and push receptacle onto powerway connector at right end of powerway Secure with 2 screws and close worksurface channel cover POWERWAY DUPLEX RECEPTACLE WORKSURFACE CHANNEL COVER ...